25
Measure the battery voltage between terminals.
Fully charged: 13.1V
Undercharge: 12.3V
*
注意
Attentions
Voltmeter shall be used for charging-state
inspection.
Charging
Connection method: Positive pole of battery charger is connected to battery positive lead
wire; Negative pole of battery charger is connected to battery negative lead wire.
Warning!
Battery shall be away from fire source.
•Shut off charger switch first before or
after charging in case sparks may be
generated at connection parts, which may
result in explosion.
•During charging, please take the current
time labeled on the battery as the basic
time.
* Attentions
•Battery quick charging is not
recommended except
in
case of
emergency.
•After charging, wait at least 30minutes
and then measure the battery voltage.
Charging current: Standard: 0.4A
Quick charging: 4.0A
Charging time:
Standard: 10-15hours
Quick charging: 30 minutes
After completion of charging: closed-circuit voltage: higher than 12.8V
KS MOTORCYCLES - http://ksmotorcycles.com
Содержание BX125
Страница 1: ...0 Model BX125 Motorcycle Service Manual ROHENTWURF DRAFT KS MOTORCYCLES http ksmotorcycles com ...
Страница 10: ...9 BX125 KS MOTORCYCLES http ksmotorcycles com ...
Страница 57: ...56 Maintain the chain looseness within the specified limits KS MOTORCYCLES http ksmotorcycles com ...
Страница 58: ...57 Inspection and Maintenance of Electrical System Charging system KS MOTORCYCLES http ksmotorcycles com ...
Страница 125: ... 124 KS MOTORCYCLES http ksmotorcycles com ...
Страница 129: ... 128 14 2 1 4 Circuit diagram of electronic fuel injection KS MOTORCYCLES http ksmotorcycles com ...
Страница 148: ... 147 BX125 Circuit Diagram ...