59
8. Inspect the entire electric load.
9. Quick charging is forbidden except in emergency.
10. During quick charging, the battery must be removed from the motorcycle first and then be
charged.
11. While battery is exchanged, please do not use liquid-feeding battery.
12. A voltmeter shall be employed to check the state of charged battery.
Service Data
Item
Specification
Battery
Capacity/type
12V-10AH/ lead-acid type
Voltage
(20
℃
)
Fully charged
13.5V
Must be charged
12.3V(stop working for one hour)
Charging current
Standard: 0.9A
,
Quick: 9A
Charging time
Standard: 10-15hours; Quick: 30minutes
Magneto
Capacity
150W/1500rpm
Coiling impedance value (20
℃
)
White-white 0.5-
10Ω
Voltage
regulator
Type
Full-wave rectification
Battery charging voltage
14.5V±0.4V/5.000rpm
Tightening torque value Tools
Rectifier bolt
5.0 N·m
Universal non-adjustable spanner
High-voltage coil pinch bolt
9.0 N·m
Flywheel remover
Testing device
Multimeter
5.2
Fault Diagnosis
No power
Battery over discharged
Wiring of battery is not connected.
Fuse fails.
Failure of power switch
Low voltage
Battery is poorly charged.
Poor contact.
Failure of charging system
Failure of voltage and current regulator
KS MOTORCYCLES - http://ksmotorcycles.com
Содержание BX125
Страница 1: ...0 Model BX125 Motorcycle Service Manual ROHENTWURF DRAFT KS MOTORCYCLES http ksmotorcycles com ...
Страница 10: ...9 BX125 KS MOTORCYCLES http ksmotorcycles com ...
Страница 57: ...56 Maintain the chain looseness within the specified limits KS MOTORCYCLES http ksmotorcycles com ...
Страница 58: ...57 Inspection and Maintenance of Electrical System Charging system KS MOTORCYCLES http ksmotorcycles com ...
Страница 125: ... 124 KS MOTORCYCLES http ksmotorcycles com ...
Страница 129: ... 128 14 2 1 4 Circuit diagram of electronic fuel injection KS MOTORCYCLES http ksmotorcycles com ...
Страница 148: ... 147 BX125 Circuit Diagram ...