Briteq BTX-700SW Скачать руководство пользователя страница 10

BRITEQ®

15

BTX-700SW

Temperature Unit

Select

Temperature Unit

, press ENTER button to confirm, present mode will blink on

the display, use UP and DOWN button to select

or

, press ENTER button to store.

Press MENU button back to the last menu or let the unit idle one minute to exit menu
mode.

Fixture Test

Enter menu mode, select

Fixture Test

, press ENTER button to confirm, use UP and

DOWN button to select

Auto Test

or

Manual Test

Auto Test

Select

Auto Test

, press ENTER button to confirm, the unit will run built-in programs to

automatically test pan, tilt, color, CMY, gobo, gobo rotation, shutter, dimmer, prism,
prism rotation, frost, zoom, iris, focus, flatb and lamp on/off. Press MENU button back
to the last menu or exit menu mode after auto test.

Manual Test

Select

Manual Test

, press ENTER button to confirm, the present channel will show on

the display, use Up and DOWN button to select channel, press ENTER button to
confirm, then use UP and DOWN button to adjust the value, press ENTER button to
store, the fixture will run as the channel value indicates. Press MENU button back to the
last menu or exit menu mode idling one minute.

(All channels value will become 0 after exiting Manual Test menu)

Fixture Information

Enter menu mode, select

Fixture Information

, press ENTER button to confirm, use

UP and DOWN button to select

Fixture Use Time, Lamp On Time

or

Firmware

Version.

Fixture Use Time

Select

Fixture Use Time

, press ENTER button to confirm, fixture use time will show on

the display, press MENU button back to exit.

Lamp On Time

Select

Lamp On Time

, press ENTER button to confirm, lamp on time will show on the

display, press ENTER button to confirm, use UP and DOWN button to select

Exit

or

Reset Time

, press ENTER button to confirm. Press MENU button back to the last

menu or exit menu mode let the unit idle one minute.

Firmware Version

Select

Firmware Version

, press ENTER button to confirm, firmware version will show

on the display, press MENU button back to exit.

Reset Functions

Enter menu mode, select

Reset Function

, press ENTER button to confirm, use UP

and DOWN button to select

Pan/Tilt, Color/CMY, Gobo, Shutter/Dimmer,

Focus/Zoom/Prism/Frost

, Iris/Flatb

or

All.

BRITEQ®

16

BTX-700SW

Pan/Tilt

Reset Pan/Tilt

Select

Pan/Tilt

, press ENTER button to confirm, use UP and DOWN button to select

Yes

(the unit will run built-in program to reset pan and tilt to their home positions) or

No

,

press ENTER button to store. Press MENU button to exit.

Color/CMY

Reset Color/CMY

Select

Color/CMY

, press ENTER button to confirm, use UP and DOWN button to

select

Yes

(the unit will run built-in program to reset color and CMY to their home

positions) or

No

, press ENTER button to store. Press MENU button to exit.

GOBO

Reset GOBO

Select

GOBO

, press ENTER button to confirm, use UP and DOWN button to select

Yes

(the unit will run built-in program to reset GOBO wheel to their home positions) or

No

,

press ENTER button to store. Press MENU button to exit.

Shutter/Dimmer

Reset Shutter/Dimmer

Select

Shutter/Dimmer

, press ENTER button to confirm, use UP and DOWN button to

select

Yes

(the unit will run built-in program to reset shutter and dimmer to their home

positions) or

No

, press ENTER button to store. Press MENU button to exit.

Focus/Zoom/Prism/Frost

Reset Focus/Zoom/Prism/Frost

Select

Focus/Zoom/Prism/Frost,

press ENTER button to confirm, use UP and DOWN

button to select

Yes

(the unit will run built-in program to reset focus, zoom, prism and

frost to their home positions) or

No

, press ENTER button to store. Press MENU button

to exit.

Iris/Flatb

Reset Iris/Flatb

Select

Iris/Flatb,

press ENTER button to confirm, use UP and DOWN button to select

Yes

(the unit will run built-in program to reset iris and flatb to their home positions) or

No

, press ENTER button to store. Press MENU button to exit.

All

Reset All

Select

All,

press ENTER button to confirm, use UP and DOWN button to select

Yes

(the unit will run built-in program to reset all motors to their home positions) or

No

,

press ENTER button to store. Press MENU button to exit.

Special Functions

Enter menu mode, select

Special Functions

, press ENTER button to confirm, use UP

and DOWN button to select

Fixture Maintenance

or

Factory Setting.

Fixture Maintenance

Select

Fixture Maintenance

, press ENTER button to confirm, use UP and DOWN

button to select

Interval

or

Remain Time

.

Interval

Select

Interval,

press ENTER button to confirm, the interval time will show on

Содержание BTX-700SW

Страница 1: ......

Страница 2: ......

Страница 3: ...e minimum distance between light output and the illuminated surface must be more than 2 5 meters Disconnect mains power before fuse lamp replacement or servicing Replace fuse lamp only with the same t...

Страница 4: ...y powerful output High quality diachronic lenses Beam angle 15 35 Movement Pan 540 Tilt 270 Pan Tilt moving speed adjustable Automatic Pan Tilt correction Easy calibration and maintenance by magnetic...

Страница 5: ...ed for transportation protection the tilt lock button 4 is pressed and 1 Arm 2 Front panel 3 head 4 Tilt lock button Black 5 Tilt unlock button Gray 6 Pan lock 7 Handle 8 Base 9 Antenna optional BRITE...

Страница 6: ...close look at the lamp To protect the lamp always turn off the lamp first via control panel or DMX controller and let the unit run at least five minutes to cool down before switching off the mains sup...

Страница 7: ...ose the submenu press the ENTER button to store and automatically return to the last menu Press MENU button or let the unit idle one minute to exit menu mode In the event of disconnecting with mains p...

Страница 8: ...button to confirm use UP and DOWN button to select Yes or No press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Reset Memory Select R...

Страница 9: ...X controller to make the lamp on BRITEQ 14 BTX 700SW Off If DMX Off l Lamp turns off when DMX signal is cut off Select Off If DMX Off press ENTER button to confirm present mode will blink on the displ...

Страница 10: ...or CMY Gobo Shutter Dimmer Focus Zoom Prism Frost Iris Flatb or All BRITEQ 16 BTX 700SW Pan Tilt Reset Pan Tilt Select Pan Tilt press ENTER button to confirm use UP and DOWN button to select Yes the u...

Страница 11: ...offset the value from 128 to 127 press ENTER button to store Press MENU button to exit Cyan Cyan home position adjust Enter offset mode Select Cyan press ENTER button to confirm the present position w...

Страница 12: ...It appears when the lamp has been on over 700 hours please turn off the lamp Memory Initial Fail It appears when the memory IC is damaged CPU B Error CPU C Error CPU D Error They appear when board P...

Страница 13: ...idle one minute to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 2...

Страница 14: ...234 255 Color11 Ch21 Focus 0 255 0 0 255 100 190 193 Stop BRITEQ 24 BTX 700SW 22 Channels mode 2 Ch5 Ch6 Ch1 Ch2 Ch3 Ch4 Shutter 22Channels Mode 2 Ch7 Ch8 Ch9 Ch10 Ch11 Color Cyan Magenta Yellow Dimme...

Страница 15: ...r Cyan Magenta Yellow 0 0 255 100 0 0 255 100 0 0 255 100 Function Pan Tilt Macro 000 007 Stop 008 015 Macro1 016 023Macro2 024 031Macro3 032 039Macro4 040 047Macro 5 056 063Macro7 064 071Macro8 072 0...

Страница 16: ...he user manual of our firmware updater not included order code 4319 to update the fixture 9 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestion...

Страница 17: ...tight as it is can easily rupture 5 Reverse the procedures from step 3 to 2 10 Maintenance and Cleaning Maintenance Ignitor Ballast Filter A As the pictures shown above please replace the cable or ca...

Отзывы: