Fixing Your Riser Rail to the Wall

Fitting the Riser Rail

Before proceeding with fitting the rail, identify each of the items 

supplied using the illustration on the right.

The Slider should not be removed from the rail during fitting. The 

underside of the slider has a button to release the slider and allows 

the height to be adjusted.

Slide the hose retainer onto the bottom end of the rail. Position a 

wall bracket onto each end of the rail, ensuring the hole through the 

top of the rail lines up with the hole in a wall bracket.

Position the rail on the wall, bearing in mind the different heights 

of people likely to use the shower and the length of the hose when 

connected to the shower and passed through the hose retainer. 

Mark the wall to indicate the upper fixing screw position. 

Warning:

 Please check for any hidden pipes and cables before 

drilling holes in the wall.

Tips:

 

A piece of insulation or masking tape positioned where holes 

are to be drilled and before marking out the exact position 

for the fixing holes will help stop the drill bit from wandering, 

particularly on a tiled surface.

When working near a basin, bath or shower insert plug or cover 

waste to prevent losing small parts.

Take care not to drop tools/equipment into basin, bath or 

shower during shower installation.

Drill the wall at the marked fixing position to suit the wall fixings to 

be used, loosely fix the rail (with the large hole on the side shown) 

and wall bracket. Check that the rail is hanging vertically using a 

spirit level. 

Slide the lower wall bracket onto the rail and mark its required 

position onto the wall. 

Note: 

The lower wall bracket does not fix to the riser tube and can 

be positioned along the riser tube so as to cover either an existing 

riser hole in the wall or over a tile joint.

Remove the lower bracket from the rail and unscrew the upper 

bracket from the wall. Mark and drill the lower wall bracket fixing 

position and fix the bracket to the wall. Slide the rail down through 

the lower wall bracket and reattach the upper bracket.

Check that the rail is perfectly vertical and tighten the upper fixing 

screw. Insert end caps into the wall brackets at both ends of the rail.

When fitting the hose, it should pass through the hose retainer. 

Note:

 The conical hose end and not the handset handle, fits into the 

slider. The slider moves more freely on the rail if gripped next to the 

rail, rather than at the handset.

Conical  

hose end

Need help?

 Give us a call on

 0844 701 6273

 and speak to one of our trained advisors.  

Slider 

Slider release  

button

Hose  

retainer

Large hole

Содержание SM385 W

Страница 1: ...Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them with the user Installation Instructions and User Guide Smile Electric Shower...

Страница 2: ...ollection has been designed to be enjoyable to fit and to use It has also been designed and tested in the UK to all of the relevant British Standards These instructions contain all of the necessary in...

Страница 3: ...object Do not operate the shower if the water stops flowing during use or if the water is leaking from the shower unit itself Turn off at the mains electrical supply and refer to the Troubleshooting...

Страница 4: ...ature is set too high and the water inside the water heater gets too hot The Temperature Control Device will switch off the power to the heating elements Once the unit cools down to a safe temperature...

Страница 5: ...ependent electrical supply It must not be connected to a ring main spur power socket or lighting circuit If you don t have a spare fuse way or the rating at the main fuse box is below 80A you should s...

Страница 6: ...arrying capacity of the cable must be at least that of the shower circuit Please refer to the table below In domestic installations you must ensure that the electrical supply and existing fuse board a...

Страница 7: ...can sit within a bath basin or shower tray you must fit a double check valve in the supply pipe work to prevent back siphonage If the showerhead can sit within a WC then the air gap should be a type A...

Страница 8: ...le pencil through the paper Remove the template from the wall and drill the wall to suit the wall fixings to be used L N Fixing Your Shower to the Wall Tips A piece of insulation or masking tape posit...

Страница 9: ...N L N Bottom left inlet entry Bottom right inlet entry Top left inlet entry Rear left inlet entry using a 15mm compression elbow not supplied Rear left inlet entry requiring rear access Rear right in...

Страница 10: ...is carefully removed to allow push fit fitting to grip the inlet pipe Inlet Entry Options The pipe work can enter the shower unit from 6 different positions Bottom left Bottom right Top left Rear left...

Страница 11: ...Water Connection The inlet pipe connection into the elbow is a self seal push fit type All burrs and rough edges must be removed from the end of the pipe before connecting To release the pipe work fr...

Страница 12: ...cal Connection Entry Point Options Select the cable inlet option most suited to your situation L N L N L N Rear bottom left cable entry Top left cable entry Rear bottom right cable entry Need help Giv...

Страница 13: ...ved The supply cable must be secured by routing through conduit or in trunking or by being embedded in the wall in accordance with current I E E Regulations Warning Do not switch on power to the showe...

Страница 14: ...osing small parts Take care not to drop tools equipment into basin bath or shower during shower installation Drill the wall at the marked fixing position to suit the wall fixings to be used loosely fi...

Страница 15: ...on the mains electrical supply to the shower Wait approximately 30 seconds for the water to flow correctly Once the water has flowed for a further 10 seconds rotate the temperature control knob 2 from...

Страница 16: ...there is always a delay of a few seconds between you selecting a temperature setting and the selected water temperature starting to flow Warning This appliance is not intended for use by persons inclu...

Страница 17: ...s regularly and before you turn the shower on to remove any scale or debris The hardness of the water in your area will determine how often you should clean your showerhead Build up of scale in partic...

Страница 18: ...etting Shower runs hot and cold during use Water pressure is at minimum requirement Check running pressure minimum of 0 7bar Wait until pressure increases Shower temperature cycles between hot and col...

Страница 19: ...Modification or repair of this product by person s not authorised by Bristan will invalidate this guarantee This guarantee does not affect your statutory rights Guarantee Service Policy Replacement Pa...

Страница 20: ...ief Diaphragm Housing x1 inc Screws x2 1 09 131 308 Pressure Relief Diaphragm Pressure Relief Diaphragm x1 1 10 131 400 S Water Inlet Elbow Ass Inlet Elbow x1 Swivel Inlet Pipe x1 Filter x1 inc O ring...

Страница 21: ...21 Spare Parts 5 1 9 13 17 2 10 14 18 6 3 11 15 19 7 4 12 16 8 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors...

Страница 22: ...ckets x2 Wall Bracket End Caps x2 Screws x2 Wall Plugs x2 1 03 207041 Riser Rail Ass Riser Rail x1 Riser Rail End Caps x2 1 04 1625A0A Slider Handset Holder Slider Handset Holder x1 1 05 11044A0A Hose...

Страница 23: ...23...

Страница 24: ...Bristan Group Ltd Birch Coppice Business Park Dordon Tamworth Staffordshire B78 1SG Web www bristan com Email enquire bristan com A Masco Company Issue FI ES Smile B Part Number 131 722...

Отзывы: