background image

12

Plumbing Connections 

cont.

Inlet connector elbow (right side down or rear)

9

8
7

Inlet connector elbow (left side, up, down or rear)

Outlet connection 

9

7
8

Warning:

 The outlet of the shower acts as a vent and must not 

be blocked, restricted or connected to any tap/closure device other 

than the handset supplied.
Do not solder within 300mm of the shower unit or allow solder or 

flux to fall onto the casings. 

Important:

 An additional independent stop valve complying with the 

current water regulations must be fitted in the mains water supply 

as a means of isolating the supply to the unit for servicing and/or 

maintenance work.  
It is essential that all pipe work is flushed through to remove debris 

and swarf that could otherwise damage the unit. Once the pipe 

work has been flushed through, turn off the water supply at the stop 

valve.
Connect the mains water supply to the inlet port of the shower using 

15mm copper pipe (BS EN1057) or 15mm plastic pipe (with insert).  

Do not

 use stainless steel pipe work. If using chrome plated pipe 

ensure that the first 25mm of plating is carefully removed to allow 

push-fit fitting to grip the inlet pipe.

Inlet Entry Options

The pipe work can enter the shower unit from 6 different positions.  

Bottom left, Bottom right, Top left, Rear left, Rear right or Rear left - 

using an elbow (as shown on page 11).

To top or bottom left positions

The shower unit should come supplied with the inlet connection set 

for a bottom left position. To change it to a top left position: swivel 

the inlet connector elbow from facing downward to facing upward. 

To bottom right position

Unfasten the screw (7) securing the inlet connector elbow clamp 

(8), remove the tab from the slot and keep until the inlet pipe is 

repositioned. Lift the outlet connection (9) up out of the way from 

its position at the bottom of the unit. Pull the inlet connector elbow 

towards you and over to the right hand side with the inlet entry 

point facing down. Refit the clamp tab (8) into the slot on the right, 

refasten the screw (7) and replace the outlet connection (9).

To rear entry positions

Swivel the inlet connector elbow to face a rear entry pipe 

connection.  

If the pipe work entry is from the rear

, ensure that there is space 

left around the push-fit elbow for future servicing or alternatively 

access is possible from the rear. Bring the cold water pipe to the 

Need help?

 Give us a call on

 0844 701 6273

 and speak to one of our trained advisors.  

Содержание Bliss BL385 W

Страница 1: ...Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them with the user Installation Instructions and User Guide Bliss Electric Showers...

Страница 2: ...tan s electric shower collection has been designed to be enjoyable to fit and to use It has also been designed and tested in the UK to all of the relevant British Standards These instructions contain...

Страница 3: ...on your hand or any other part of your body or foreign object Do not operate the shower if the water stops flowing during use or if the water is leaking from the shower unit itself Turn off at the ma...

Страница 4: ...around the unit as this may prevent air circulating and condensation escaping This shower unit must not be modified in any way as this will invalidate the guarantee Except for top left pipe entry see...

Страница 5: ...erature is set too high and the water inside the water heater gets too hot The Temperature Control Device will switch off the power to the heating elements Once the unit cools down to a safe temperatu...

Страница 6: ...tem Requirements Suitable for mains cold water pressure only Electrical cable entry points Left hand side Top Bottom Rear bottom Right hand side Bottom Rear bottom Product Fiche Model BL385 W BL395 W...

Страница 7: ...ectrical supply It must not be connected to a ring main spur power socket or lighting circuit If you don t have a spare fuse way or the rating at the main fuse box is below 80A you should seek advice...

Страница 8: ...g factors Electrical Requirements cont Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors On installation of the appliance the impedance measurement of the Neutral and...

Страница 9: ...work to prevent back siphonage If the showerhead can sit within a WC then the air gap should be a type AUK3 not less than 20mm or twice the diameter of the inlet pipe to the fitting whichever is the...

Страница 10: ...paper Remove the template from the wall and drill the wall to suit the wall fixings to be used L N Fixing Your Shower to the Wall Tips A piece of insulation or masking tape positioned where holes are...

Страница 11: ...t inlet entry Bottom right inlet entry Top left inlet entry Rear left inlet entry using a 15mm compression elbow not supplied where NO rear access is available Rear left inlet entry requiring rear acc...

Страница 12: ...ng to grip the inlet pipe Inlet Entry Options The pipe work can enter the shower unit from 6 different positions Bottom left Bottom right Top left Rear left Rear right or Rear left using an elbow as s...

Страница 13: ...for water leaks at the shower inlet Once inspected turn off the water supply Pressure Relief Device PRD A pressure relief device is designed into this shower The pressure relief device provides prote...

Страница 14: ...and 8 Electrical Connection Entry Point Options Select the cable inlet option most suited to your situation L N L N Rear bottom left cable entry Top left cable entry Rear bottom right cable entry Note...

Страница 15: ...and entry point used it may be necessary to strip back outer cable sheath sufficiently to allow cables to be directed to the terminal connection block within the unit Note When feeding cable through b...

Страница 16: ...ctor must be sleeved The supply cable must be secured by routing through conduit or in trunking or by being embedded in the wall in accordance with current I E E Regulations Warning Do not switch on p...

Страница 17: ...into basin bath or shower during shower installation Drill the wall at the marked fixing position to suit the wall fixings to be used loosely fix the rail with the large hole on the side shown and wal...

Страница 18: ...the water to flow correctly Once the water has flowed for a further 10 seconds rotate the temperature control knob 6 from the fully clockwise position to the fully anti clockwise position Repeat this...

Страница 19: ...ss the STOP START touch button 3 Phased Shut Down When the shower is turned off water will continue to flow for a short period of time while the heater cools down This ensures that the shower is ready...

Страница 20: ...be cleaned with a soft clean damp cloth Performance Maintenance Indication Display shows CL This is a performance Maintenance Indication that routine service cleaning is advisable to maintain showeri...

Страница 21: ...mum requirement Check running pressure minimum of 0 7bar Wait until pressure increases Shower temperature cycles between hot and cold Shower temperature is set too high causing the thermal cut out to...

Страница 22: ...been misused or damaged Modification or repair of this product by person s not authorised by Bristan will invalidate this guarantee This guarantee does not affect your statutory rights Guarantee Serv...

Страница 23: ...Housing Ass Pressure Relief Diaphragm Housing x1 inc Screws x2 1 07 131 308 Pressure Relief Diaphragm Pressure Relief Diaphragm x1 1 08 131 400 S Water Inlet Ass Inlet Elbow x1 Swivel Inlet Pipe x1 Fi...

Страница 24: ...24 Spare Parts Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors 3 1 7 11 14 8 12 4 9 13 16 5 2 10 17 6 15...

Страница 25: ...ser Rail End Cap x1 2 02 11043A0A Wall Bracket Ass Wall Brackets x2 Wall Bracket End Caps x2 Screws x2 Wall Plugs x2 1 03 207041 012C Riser Rail Ass Riser Rail x1 Riser Rail End Caps x2 1 04 1625A0A S...

Страница 26: ...lease use this space to add any notes you or your installer may have regarding the plumbing system installation of this product Need help Give us a call on 0844 701 6273 and speak to one of our traine...

Страница 27: ...lease use this space to add any notes you or your installer may have regarding the plumbing system installation of this product Need help Give us a call on 0844 701 6273 and speak to one of our traine...

Страница 28: ...Bristan Group Ltd Birch Coppice Business Park Dordon Tamworth Staffordshire B78 1SG Web www bristan com Email enquire bristan com A Masco Company Issue FI ES Bliss I Part Number 131 724...

Отзывы: