BE6100 

Edition 08/2018 

Page 9 of 13 

 

Turn off motor 

 

Open terminal box and disconnect the power 
leads. 

 

Close all valves!  

 

Empty out the pump. 

 

Remove all materials which could potentially 
cause harm to humans or the environment!  

 

Coolants must not pollute the environment!  

 

Depressurize the system! 

 

When handling toxic materials, wear safety 
glasses, protective clothing and protective 
gloves!

 

7  Operation 

7.1  Liquid level 

 

Check for proper liquid level.  

 

The minimum liquid level (H, see drawing 1) 
should be 70 mm for BFS1, BFS2, and TFS3, 
100 mm for TFS4 and TFS5 and 150 mm for 
TFS6. 

 

Maximum liquid level is 35 mm below the 

pump’s mounting plate. 

 

The distance between the suction pipe and the 
bottom of the tank is 100 mm for BFS1, BFS2, 
TFS3, TFS4 and TFS5 and 150 mm for TFS6. 
These distances must be adhered to. 

 

Using the patented Brinkmann suction protector 
prevents large particles and foreign objects from 
entering the screw pump. The protector extends 
the life expectancy of the pumps significantly. In 
addition, the large surface area of the suction 
protector prevents the pump from drawing air 
which can be caused by a funneling effect at the 
suction pipe if no suction protector is used. 

 

The pump may only be installed and operated in 
a suitable container! 

 

Operation is only permitted with a suction pipe, 
suction line or suction protector. 

 

 ATTENTION  

Never operate screw pumps dry.

 

Sufficient fluid level must always be ensured. 

Avoid hydraulic shocks!

 

7.2  Signs of abnormal operating behaviour 

 

Discolouration, noises and vibrations in the 
vicinity of the adaptor cap point to problems with 
the main drive spindle bearing. In order to avoid 
hazards, the pump should be put out of service 
immediately! 

 

When the pump noise increases, this indicates 
to a medium with insufficient lubricity, or wear 
and tear.  

 

If the noise increases to a level which is no 
longer permitted or in the case of strong vibra-
tions, the pump should be exchanged immedi-
ately. 

7.3  Operation with a frequency inverter 

 

When operating with a frequency inverter, the 
user must ensure that it has a safety reserve of 
10% in terms of the nominal voltage of the mo-
tor. In addition, the size of the motor should pro-
vide a safety margin of 10 % with respect to the 
max. pump output. 

 

When operating with a frequency inverter it is 
necessary to follow the permitted minimum 
speeds and maximum speeds. These depend 
on the pressure, medium and pump model. If 
necessary, consult with the factory. 

 

Please follow the separate operating instructions 
for the frequency inverter (jointly supplied). 

 

7.4  Operation with a pressure relief valve 

 

When operating with a pressure relief valve the 
user should bear in mind that the self-setting 
operating pressure depends on the flow rate, 
especially in the case of spring-controlled 
valves. As such, the operating pressure should 
not be insignificantly above the opening pres-
sure of the valve. The motor power is to be ade-
quately rated according to the maximum prevail-
ing pressure. 

 

In addition, please follow the separate operating 
instructions for the pressure relief valve (jointly 
supplied). 

7.5  Operation with mechanical seal -G and 

FFS pump series (inline)

 

 

The mechanical seal gets damaged and de-
stroyed by pressure spikes, which therefore 
must be avoided on the system side. Pumps 
equipped with the -G4 feature are not affected 
by this. 

 

Due to the design principles of mechanical 
seals, leakage flow always occurs. The lekage 
can (if necessary) be captured and redirected 
from the threaded opening in the bearing cover. 

 

Please ensure that pumps equipped with me-
chanical seal -G or of the FFS series pumps 
(inline version) have always a flooded suction 
and are operated with a positive supply pres-
sure.  Operating these pumps under negative 
pressures can cause mechanical seal damage / 
failure due to lack of lubrication on the seal 
faces. Pumps equipped with the -G4 feature are 
not affected by this. 

 
 
 
 
 
 
If  the  pump  becomes  blocked,  do  not  operate 
the pump any longer (see point 6.3) and send it 
to the manufacturer for repair. 
 

8  Servicing and Maintenance 

 ATTENTION  

 

The surface of the motor must be kept free of 
dirt.  

 

BRINKMANN-Screw pumps are maintenance 
free. 

 

In case of damage, pump must be sent back to 
the manufacturer. 

 

Unauthorized repair work or opening of the 
pump will void all warranties! 

 

 

Содержание BFG Series

Страница 1: ...ge 1 of 13 BRINKMANN Screw Pump BFS TFS FFS BFS H TFS H BFG FFG Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 18...

Страница 2: ...high backpressure The dis charge pressure needs to be at least 2 bar higher than the inlet pressure 2 2 Application range Screw pumps are designed for pumping filtered lubricating fluids Please consul...

Страница 3: ...tting oils coolants Max delivery pressure 60 bar BFG FFG with cast iron spindle housing 150 bar 200 bar for BFS FFS1 BFS FFS2 and TFS BFS FFS3 upon request 120 bar H Minimum dis charge pressure Ensure...

Страница 4: ...may be performed by the machine manufac turer or supplier on behalf of the plant operator Moreover the plant operator is to make sure that the contents of the operating manual are fully understood by...

Страница 5: ...shaft 1 counterclockwise Keep pump tilted until it is completely drained Pumps with mechanical seal G or axial thrust A 6 Place pump on a work bench 7 horizontally with the threaded port facing up The...

Страница 6: ...hoses should only be per formed by authorized specialists and must consider the applicable standards and local legislation Only use components which are rated for high pressure i e no brass Do not us...

Страница 7: ...lar case ATTENTION Defective pressure relief valves may lead to pump dam age Excess pressure can also damage other system compo nents or cause human injuries Do not direct the bypass flow from the pre...

Страница 8: ...thermal shock After connecting the electrical wires close the terminal box switch on the motor and check for the direction of rotation in the following manner ATTENTION The motor s direction of rotat...

Страница 9: ...t ensure that it has a safety reserve of 10 in terms of the nominal voltage of the mo tor In addition the size of the motor should pro vide a safety margin of 10 with respect to the max pump output Wh...

Страница 10: ...is cavitating because the temperature of the pumped liquid is too high Increase the supply or inlet pressure Lower the temperatur of the pumped liquid Consult with the manufacturer System pressure is...

Страница 11: ...from the nameplate 4 Spare part with item No e g Motor 1 11 Repair Instructions 11 1 Fitting the coupling Coat pump and motor shaft ends with a thin coat of Molykote e g Molybdenumdisulfphite and ins...

Страница 12: ...1 295 320 315 110 0 3 0 310 Dim A Distance between inner surface of the coupling hub and the motor shaft end Dim B Distance between inner surface of the coupling hub and pump shaft end Inner surface...

Страница 13: ...Conform ment l annexe I N 1 5 1 de la Directive Machines 2006 42 CE les objectifs de s curit relatifs au mat riel lectrique de la Directive Basse Tension 2014 35 UE ont t respect s Con respecto al po...

Отзывы: