BE6100 

Edition 08/2018 

Page 8 of 13 

5.2  Electric wiring 

 

Verify  that  there  is  no  voltage  at  the  terminal 
board! 

The  motor  is  surface-cooled  and  compliant  with  DIN 
IEC 34 and EN 60034 (protection degree IP 55). 

According to the European Standard EN 809 a  motor 
overload must be installed and properly set to the full 
load amps stated on the pump name plate. 

It  is  the  responsibility  of  the  machine  operator  to 
decide whether or not an additional emergency switch 
must be installed. 

5.2.1 

Circuit 

 

Tension  voltage  and  frequency  must  correspond  with 
the shown specification on the nameplate. 
The  pump  must  be  wired  so  that  a  solid  longterm 
electrical  connection  is  ensured.  Establish  a  solid 
ground connection. 

The  electrical  wiring  must  be  performed  accord-
ing  to  the  wiring  diagram  shown  inside  the  termi-
nal  box  cover.  (Please  see  above  sample  wiring 
diagrams) 

Wiring diagram e.g. 

Standard motors are operated in the delta connection 
but  can  also  be  started  up  with  a  star-delta  start  up 
unit in order to reduce the in rush current. In this case, 
make  sure  you  start  up  the  pump  with  minimal  back 
pressure,  as  otherwise  the  pump  may  run  backwards 
when switching over from star to delta! 

There may be no foreign objects such as dirt, particles 
or humidity inside the terminal board. 

Mount terminal board cover to motor tight against dust 
and humidity and close up all unused wiring ports. 

 ATTENTION  

When Variable Frequency Drives are used interfer-ing 
signals might occur. 

Non-sinus shaped supply voltage from a variable 
frequency drive might result in elevated motor tem-
peratures. 

6  Start up / Shut down 

6.1  Start up / Turn motor on 

 

Open all valves in discharge line completely and 
de-energize pressure relief valve (start up pump 
without any backpressure). 

 

Open the shutt off valve on the suction-side of the 
pump. 

 

Ensure sufficient liquid level in tank.  

 

In case of a horizontal installation, the pump must 
be filled prior to initial start-up. 

 

Attention!  The temperature difference between 
pump and the pumped medium should be minimal 
prior to start-up to avoid thermal shock! 

 

After connecting the electrical wires, close the 
terminal box, switch on the motor and check for the 
direction of rotation in the following manner: 

 ATTENTION  

 

The motor’s direction of rotation must correspond 
with the pump’s directional arrow (direction of rota-
tion is clockwise with a view onto the fan cover).  

 

Check the pumps operation with 2 people, i.e. 1 
person should start the motor as recommended 
(running for 1 sec. max.) and the other person 
should monitor the direction of the motor. 

 

It is not permitted to run the pump without any 
medium (dry run). This can damage the pump. Do 
not put defective pumps back into operation! 

 

Check suction and pressure pipes for any leaks; 
avoid admission of air into the pump system.  

 

Monitor pressure and temperature monitoring 
devices frequently.  

6.1.1 

Initial start-up of pumps with mechani-
cal seal 

–G 

 

During the initial start 

–up or after longer storage 

spray the interior of the pump with spray oil and 
turn by hand if applicable. 

 

Start pump with minimized pressure and bleed air 

completely (short run time!) 

 

Maximum operating pressure must be reached 

immediately afterwards resulting in ventilation and 
lubrication of the sealing area. 

Foot-mounted inline Pumps with FFS-Standard 

 

Operating pressure must be larger than incoming 

supply pressure at the pump suction,  

Attention!

 Danger of overheating the seal 

 

No negative pressure or vacuum conditions on the 

suction side,  

Attention! 

Dry running of the mechanical seal. 

 

6.2  Turn off  

 

Turn off motor.  

 

For longer downtime periods, dismantle and 
preserve pump 

6.3  Shut down  

 

All service work must be carried out by qualified 
service personnel. Pump must be disconnected 
from the power source and all rotating parts must 
stand still. Reassure that pump is disconnected 
from power source and cannot be switched on. 

 

Verify that there is no voltage at the terminal 
board! 

 

Star connection  

(Standard up to 5.5 kW) 

3 x 400 V, 50 Hz 

resp.  380-415 V, 50 Hz 

 

resp. 

 

 

 

Delta connection  

(Standard as of 6.0 kW) 

3 x 400 V, 50 Hz 

resp. 380-415 V, 50 Hz

 

 

All  service  work  must  be  carried  out  by  qualified 
service personnel. Pump must be disconnected from 
the  power  source  and  all  rotating  parts  must  stand 
still.  Reassure  that  pump  is  disconnected  from 
power source and cannot be switched on. 

Содержание BFG Series

Страница 1: ...ge 1 of 13 BRINKMANN Screw Pump BFS TFS FFS BFS H TFS H BFG FFG Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 18...

Страница 2: ...high backpressure The dis charge pressure needs to be at least 2 bar higher than the inlet pressure 2 2 Application range Screw pumps are designed for pumping filtered lubricating fluids Please consul...

Страница 3: ...tting oils coolants Max delivery pressure 60 bar BFG FFG with cast iron spindle housing 150 bar 200 bar for BFS FFS1 BFS FFS2 and TFS BFS FFS3 upon request 120 bar H Minimum dis charge pressure Ensure...

Страница 4: ...may be performed by the machine manufac turer or supplier on behalf of the plant operator Moreover the plant operator is to make sure that the contents of the operating manual are fully understood by...

Страница 5: ...shaft 1 counterclockwise Keep pump tilted until it is completely drained Pumps with mechanical seal G or axial thrust A 6 Place pump on a work bench 7 horizontally with the threaded port facing up The...

Страница 6: ...hoses should only be per formed by authorized specialists and must consider the applicable standards and local legislation Only use components which are rated for high pressure i e no brass Do not us...

Страница 7: ...lar case ATTENTION Defective pressure relief valves may lead to pump dam age Excess pressure can also damage other system compo nents or cause human injuries Do not direct the bypass flow from the pre...

Страница 8: ...thermal shock After connecting the electrical wires close the terminal box switch on the motor and check for the direction of rotation in the following manner ATTENTION The motor s direction of rotat...

Страница 9: ...t ensure that it has a safety reserve of 10 in terms of the nominal voltage of the mo tor In addition the size of the motor should pro vide a safety margin of 10 with respect to the max pump output Wh...

Страница 10: ...is cavitating because the temperature of the pumped liquid is too high Increase the supply or inlet pressure Lower the temperatur of the pumped liquid Consult with the manufacturer System pressure is...

Страница 11: ...from the nameplate 4 Spare part with item No e g Motor 1 11 Repair Instructions 11 1 Fitting the coupling Coat pump and motor shaft ends with a thin coat of Molykote e g Molybdenumdisulfphite and ins...

Страница 12: ...1 295 320 315 110 0 3 0 310 Dim A Distance between inner surface of the coupling hub and the motor shaft end Dim B Distance between inner surface of the coupling hub and pump shaft end Inner surface...

Страница 13: ...Conform ment l annexe I N 1 5 1 de la Directive Machines 2006 42 CE les objectifs de s curit relatifs au mat riel lectrique de la Directive Basse Tension 2014 35 UE ont t respect s Con respecto al po...

Отзывы: