BRINKMANN-Screw Pump Type BFS / TFS / FFS

 

Contents   

1

 

Indication to the manual .................................... 2

 

2

 

Description of product and working principle .. 2-3

 

3

 

Safety instructions .......................................... 4-5

 

4

 

Transport, and Temporary storage  ................... 5

 

5

 

Installation / Connection ................................. 6-8

 

6

 

Start up / Shut down .......................................... 8

 

7

 

Operation ........................................................... 9

 

8

 

Servicing and Maintenance ............................... 9

 

  9

 

Trouble shooter’s guide ................................... 10

 

10

 

Spare part ....................................................... 11

 

11

 

Repair Instructions ..................................... 11-12

 

12

 

Disposal .......................................................... 12

 

13

 

EC declaration of conformity ........................... 13

 

 

1  Indication to the manual 

This  operating  manual  gives  basic  instructions 
which are to be observed during installation, opera-
tion  and  maintenance  of  the  pump.  It  is  therefore 
imperative that this manual be read by the respon-
sible personnel and operator prior to assembly and 
commissioning.  It  is  always  to  be  kept  available  at 
the installation site. 

1.1  Identification of safety instructions in the 

operating manual 

Safety  instructions  given  in  this  manual  non-
compliance  with  which  would  affect 

safety

  are 

identified by the following symbol 

 

Safety sign according with ISO 3864

–B.3.1 

or where 

electrical safety

 is involved, with 

 

Safety sign according with ISO 3864

–B.3.6 

Where  non-compliance  with  the  safety  instructions 
may  cause  a  risk  to  the  machine  and  it’s  function 
the word 

 ATTENTION  

is inserted. 

2  Description of product and working 

principle 

2.1  Scope  

Pumping of fluids at

 

high backpressure. The dis-

charge pressure needs to be at least 2 bar higher 
than the inlet pressure. 

2.2  Application range 

  Screw pumps are designed for pumping filtered, 

lubricating fluids (Please consult with the manu-
facturer for specific applications). 

  Screw  pumps  are  used  in  applications  where 

high  pressures  and  constant  flow  rates  are  re-
quired    (e.g.  general  machine  design,  machine 
tool industry, etc.) 
Operate pump within the design limititations and 
in accordance with section 2.6. 

2.3  Working principle

  

  The  intermeshing  threads  of  three  screw  spin-

dles generate liquid holding chambers. 

  The center spindle  is driven and  all three screw 

spindles rotate.  

  The    medium  moves  continuously  and  without 

noticeable pulsation toward the pump discharge. 

  Proper clockwise rotation must be ensured at all 

times.  Incorrect  counterclockwise  rotation  will 
result  in  dry  running  and  pump  damage.  Cata-
strophic failure is possible! 

  Screw  pumps  are  self-priming,  however,  dry 

running  must  be  avoided  under  any  circum-
stances  as  it  will  almost  instantly  damage  the 
pump and it might result in catastrophic failure. 

  Screw  pumps  are  positive  displacement  pumps 

and must therefore always be used in combina-
tion  with  a  pressure  limiting  valve  or  pressure 
relief valve.  

 

2.4  Type code structure (example) 

High pressure screw pump: 

BFS 250 / 80  -G  

Pump series designation 
BFS, TFS or FFS 
Pump size 
Maximum pressure in bar 
Special features  

(e.g. with mechanical seal)  

2.5  Pump Models 

Immersion style 
BFS, TFS  

(-H) pressure outlet above tank plate 

FFS foot mounted inline style 

 

 

 

Содержание BFG Series

Страница 1: ...ge 1 of 13 BRINKMANN Screw Pump BFS TFS FFS BFS H TFS H BFG FFG Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 18...

Страница 2: ...high backpressure The dis charge pressure needs to be at least 2 bar higher than the inlet pressure 2 2 Application range Screw pumps are designed for pumping filtered lubricating fluids Please consul...

Страница 3: ...tting oils coolants Max delivery pressure 60 bar BFG FFG with cast iron spindle housing 150 bar 200 bar for BFS FFS1 BFS FFS2 and TFS BFS FFS3 upon request 120 bar H Minimum dis charge pressure Ensure...

Страница 4: ...may be performed by the machine manufac turer or supplier on behalf of the plant operator Moreover the plant operator is to make sure that the contents of the operating manual are fully understood by...

Страница 5: ...shaft 1 counterclockwise Keep pump tilted until it is completely drained Pumps with mechanical seal G or axial thrust A 6 Place pump on a work bench 7 horizontally with the threaded port facing up The...

Страница 6: ...hoses should only be per formed by authorized specialists and must consider the applicable standards and local legislation Only use components which are rated for high pressure i e no brass Do not us...

Страница 7: ...lar case ATTENTION Defective pressure relief valves may lead to pump dam age Excess pressure can also damage other system compo nents or cause human injuries Do not direct the bypass flow from the pre...

Страница 8: ...thermal shock After connecting the electrical wires close the terminal box switch on the motor and check for the direction of rotation in the following manner ATTENTION The motor s direction of rotat...

Страница 9: ...t ensure that it has a safety reserve of 10 in terms of the nominal voltage of the mo tor In addition the size of the motor should pro vide a safety margin of 10 with respect to the max pump output Wh...

Страница 10: ...is cavitating because the temperature of the pumped liquid is too high Increase the supply or inlet pressure Lower the temperatur of the pumped liquid Consult with the manufacturer System pressure is...

Страница 11: ...from the nameplate 4 Spare part with item No e g Motor 1 11 Repair Instructions 11 1 Fitting the coupling Coat pump and motor shaft ends with a thin coat of Molykote e g Molybdenumdisulfphite and ins...

Страница 12: ...1 295 320 315 110 0 3 0 310 Dim A Distance between inner surface of the coupling hub and the motor shaft end Dim B Distance between inner surface of the coupling hub and pump shaft end Inner surface...

Страница 13: ...Conform ment l annexe I N 1 5 1 de la Directive Machines 2006 42 CE les objectifs de s curit relatifs au mat riel lectrique de la Directive Basse Tension 2014 35 UE ont t respect s Con respecto al po...

Отзывы: