Read this manual thoroughly before installation and operation. DO NOT proceed with installation and operation
if you have any questions of do not understand anything in this manual. Contact your local representative.
Select a location for the griddle that has a level, solid, non-slippery surface that is nonflammable and away
from water hazards or sinks, and is in a well-lighted work area away from children and visitors.
Equipment must be installed under proper ventilation as required per local code.
NOTICE:
Local codes regarding installation and ventilation vary greatly by area. The National Fire Protection
Association, Inc. states in its NFPA 96 latest edition (see NFPA page at the beginning of this manual) that
local codes are “authority having jurisdiction” when it comes to requirements for installation of equipment.
Therefore, installation should comply with all local codes.
This appliance is equipped for Natural gas, for conversion to LP gas. Please see conversion kits instructions.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Legs must
be installed to adequately provide proper ventilation to the unit.
Level unit by adjusting the four feet and tighten securely. The adjustable feet have an adjustment of one inch
for lineup with other countertop lines. Do not slide unit with legs mounted, lift if necessary to move unit.
The supplied gas pressure regulator is factory set a 4” Natural gas W.C. or 10” for L.P.
THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.
Noncombustible clearances: 0” side (0 mm) 6” rear (152 mm) 4”floor (102mm).
Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the
flue. Do not place objects between the bottom of the unit and the counter top.
There must be adequate clearance for removal of the front panel. All major parts except the burners are
removable thru the front if the gas line is disconnected.
It may be necessary to adjust the balance of gas volume and air supply to each burner. This must be done by
an authorized service technician.
Pipe threading compound must be resistant to the action of liquefied petroleum gases.