Electrical and Fuel Inlet Locations
The 3/4 inch N.P.T. fuel inlet connector (
A
) and electrical
inlet location (
B
) is shown below.
A ½ inch knock-out is provided for the electrical inlet. This
inlet may be enlarged or supplemented to accommodate
a maximum conduit size of 1 ½ inches. Ensure that the
installed conduit(s) enter the unit in the zone (
C
) shown in
the drawing such that they properly enter the electrical box
and do not interfere with the fully opened roof.
The home generator is supplied with a base that, unless
mandated by local code, does not require a concrete slab.
A
B
C
Not for
Reproduction