Step 4: Connecting Electrical Loads   Figure

 

1

Generator may only be loaded up to rated power under 

the rated conditions as shown on unit data tag. Reduce 

load when using generator outside of rated conditions.

Use only high quality, well-insulated extension cables in 

accordance with IEC 245-4 with the generator’s 230 Volt 

AC outlets. Inspect extension cables before each use. 

Check that all extension cables are suitably rated and 

are not damaged. When using extension cords under 40° 

C, the total length of cords for a cross section of 1.5 mm² 

should not exceed 50 m or for a cross section of 2.5 mm² 

should not exceed 80 m.

WARNING! 

  Damaged or overloaded extension 

cords could overheat, arc, and burn resulting in 

death or serious injury.

•  Electrical equipment, including cables and plug 

connections, should not be defective. 

230 Volt AC Receptacles

Use receptacles (

R

) to operate 230 Volt AC, single-phase, 

50 Hz electrical loads. The receptacle is protected against 

overload by a push-to-reset circuit breaker (

K

).

Protection of electrical components depends on circuit 

breakers specifically matched to the generator. Replace 

circuit breaker with identical rating and performance 

characteristics.

WARNING! 

  Generator voltage could cause 

electrical shock or burn resulting in death or 

serious injury. 

•  Do not touch bare wires or receptacles. 

•  Do not use generator with electrical cords which are 

worn, frayed, bare or otherwise damaged. 

•  Do not operate generator in the rain or wet weather. 

•  Do not handle generator or electrical cords while 

standing in water, while barefoot, or while hands or feet 

are wet. 

•  Do not allow unqualified persons or children to operate 

or service generator. 

•  Keep children a safe distance from generator.

12 Volt DC Receptacle

The maximum current available for the 12 Volt DC 

receptacle (

G

) is 60 Watts (5 Amps). A DC circuit 

breaker (

H

) protects this receptacle from overloads. If an 

overload occurs, the circuit breaker will trip (push button 

pops out). Wait a few minutes and push the button in to 

reset the circuit breaker.

This receptacle along with the USB adapter allows you to 

recharge any USB powered device with a USB charging 

cable (not included).

NOTICE

   For charging ITE (Information Technology 

Equipment) only.

NOTICE

  

 When using this receptacle, push the QPT 

switch to the OFF (0) position.

LED Panel      Figure 

7

Output Indicator   

The green LED output indicator light comes on when 

the generator is operating normally. It indicates that the 

generator is producing power at the receptacles.

Overload Alarm   

The red LED overload alarm light comes on and cuts 

power to the receptacles if you overload the generator. 

The green output indicator light will also go off. If the 

generator was overloaded, you must turn off and unplug 

all electrical loads, then push the generator reset button 

to continue operating.

Low Oil Indicator   

The low oil indicator system is designed to prevent 

engine damage caused by not enough engine oil. If the 

engine oil level drops below a preset level, the yellow 

LED low oil indicator light comes on and an oil switch will 

stop the engine. If the engine stops or the yellow LED 

low oil indicator light comes on when you pull the recoil 

handle, check the engine oil level.

Parallel Operation

Two Briggs & Stratton inverter generators can be run 

in parallel with a Briggs & Stratton parallel operation kit 

(optional equipment). When running in parallel, the total 

output of power is shown in chart.

Models

Maximum Output

P2200 & P2200

3000 Watts

P2200 & P3000

3000 Watts

P3000 & P3000

4800 Watts

NOTICE   

Total electrical load connected to the parallel 

kit must not exceed the maximum output.

See the parallel operation kits instruction sheet for 

detailed instructions on installation and operation of the 

connected generators.

Step 5: Generator Shut Down

  1.  Turn off and unplug all electrical loads from generator 

panel receptacles. Never  stop engine with electrical 

devices plugged in and turned on.

  2.  Let engine run at no-load for one minute to stabilize 

internal temperatures of engine and generator.

  3.  Push engine switch to OFF (0) position.

Содержание 030698

Страница 1: ...Groupe Electrogène Notice d Utilisation 01 001557 220920 P2200 Code 030698 Retrouvez nous sur www iseki fr ...

Страница 2: ......

Страница 3: ...ll rights reserved BRIGGS STRATTON is a registered trademark of Briggs Stratton Corporation en English ar العربية bg български език cs Čeština da Dansk de Deutsch el Ελληνικά es Español et Eesti keel fi Suomi fr Français hr Hrvatski hu Magyar it Italiano lt Lietuvių k lv Latviešu nl Nederlands no Norsk pl Polski pt Português ro Română ru Pусский sk Slovenčina sl Slovenščina sv Svenska sw Kiswahili...

Страница 4: ...N o t f o r R e p r o d u c t i o n 2 BRIGGSandSTRATTON COM E D R K V F U T M H G B A C S 1 J L R 16A 13A P N ...

Страница 5: ...N o t f o r R e p r o d u c t i o n 3 2 10 B A 8 3 A 6 5 4 11 7 C B D A 9 13 12 ...

Страница 6: ... this manual is accurate and current However the manufacturer reserves the right to change alter or otherwise improve the generator and this document at any time without prior notice NOTICE If you have questions about intended use contact an authorized service dealer This equipment is designed to be used with Briggs Stratton authorized parts ONLY System Ground The generator has a system ground tha...

Страница 7: ...onoxide poisoning Operation Location of Portable Generator to REDUCE THE RISK OF FIRE WARNING Exhaust heat gases could ignite combustibles structures or damage fuel tank causing a fire resulting in death or serious injury Portable generator must be at least 1 5 m 5 ft from any structure overhang trees windows doors any wall opening shrubs or vegetation over 30 5 cm 12 in in height Do not place por...

Страница 8: ... cigarette or smoke Do not pour water on generator to put out fire Only use a extinguisher rated for flammable liquids and electrical systems such as a powder extinguisher Follow the instructions provided by fire extinguisher manufacturer before use This generator is not for use in explosive atmospheres 1 Slowly remove fuel cap 1 V to relieve pressure in tank 2 Slowly add unleaded fuel to red fuel...

Страница 9: ... circuit breaker will trip push button pops out Wait a few minutes and push the button in to reset the circuit breaker This receptacle along with the USB adapter allows you to recharge any USB powered device with a USB charging cable not included NOTICE For charging ITE Information Technology Equipment only NOTICE When using this receptacle push the QPT switch to the OFF 0 position LED Panel Figur...

Страница 10: ...ncer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Change oil while engine is warm from running as follows 1 Make sure generator is on a level surface 2 Loosen side maintenance cover screws and remove cover 3 Clean area around oil fill and remove oil fill cap 4 Tip...

Страница 11: ...ommend that you have a Briggs Stratton Authorized Service Dealer check and adjust valve clearance at recommended intervals see Maintenance Schedule Storage If storing the unit for more than 30 days use the following guidelines to prepare it for storage Change Engine Oil While engine is still warm drain oil from crankcase Refill with recommended grade See Changing Engine Oil Protect Fuel System Fue...

Страница 12: ...nk engine For all other issues see a Briggs Stratton Authorized Dealer Troubleshooting This generator is rated in accordance with Briggs Stratton 628K Starting Watts represents the momentary electrical current the generator can provide to start electric motors Starting Watts does not represent the power required to continuously run electrical loads Starting Watts is the maximum current that can mo...

Страница 13: ... initial purchase date at the time warranty service is requested the manufacturing date of the product will be used to determine the warranty period Product registration is not required to obtain warranty service on Briggs Stratton products ABOUT YOUR WARRANTY Warranty service is available only through Briggs Stratton Authorized Service Dealers Most warranty repairs are handled routinely but somet...

Страница 14: ...rer ou d améliorer le produit et ce document à tout moment et sans préavis AVIS Pour toutes questions sur l utilisation prévue contactez un revendeur autorisé Cet équipement est désigné pour être utilisé avec les pièces détachées de Briggs Stratton SEULEMENT Système de mise à la terre Le générateur dispose d un système de mise à la terre qui relie les composants du cadre du générateur aux bornes d...

Страница 15: ...au monoxyde de carbone Emplacement de fonctionnement du générateur portable pour RÉDUIRE LES RISQUES D INCENDIE AVERTISSEMENT Les émissions de chaleur gaz pourraient enflammer les produits combustibles les structures ou les réservoirs de carburant et endommager le réservoir d essence en provoquant un incendie et entraîner la mort ou de graves blessures Le générateur portable doit être disposé à au...

Страница 16: ...aleur et de toute autre source d allumage Vérifiez les durites d essence le capuchon et les joints fréquemment pour visualiser des craquelures ou des fuites Remplacez si nécessaire Ne pas allumer de cigarette ni fumer N essayez pas d éteindre le générateur en feu avec de l eau Utilisez uniquement un extincteur homologué pour feux de liquides et de systèmes électriques inflammables tel qu un extinc...

Страница 17: ...maximal disponible pour la prise de 12 Volt CC G est 60 Watts 5 A Un coupe circuit CC H protège cette prise des surcharges Si une surcharge se produit le disjoncteur se déclenche le bouton poussoir saute Attendez quelques minutes et poussez le bouton pour réinitialiser le disjoncteur Cette prise couplée de cet adaptateur USB vous permet de recharger tout dispositif alimenté par USB avec un câble d...

Страница 18: ...au au contact d huile moteur usagée Lavez les surfaces exposées avec de l eau et du savon GARDEZ HORS DE LA PORTÉE DES ENFANTS NE POLLUEZ PAS CONSERVEZ LES RESSOURCES RETOURNEZ L HUILE USAGÉE AUX CENTRES DE COLLECTE Changez l huile lorsque le moteur est encore chaud après avoir tourné de la manière suivante 1 Assurez vous que le générateur se trouve sur une surface plane 2 Desserrez deux vis du co...

Страница 19: ...e le contrôle et le réglage du jeu de soupape soit effectué par un technicien agréé Briggs Stratton aux intervalles recommandés voir Calendrier d entretien Entreposage Si vous n utilisez pas votre groupe électrogène pendant plus de 30 jours reportez vous aux indications suivantes pour le préparer au stockage Changement de l huile moteur Le moteur encore chaud vidangez l huile du carter Remplissez ...

Страница 20: ...ectez le fil à la bougie 6 Attendre 5 minutes et relancez le moteur Pour toutes autres questions voir un revendeur Briggs Stratton Diagnostic Selon la norme 628K de Briggs Stratton le watt de démarrage représente le courant électrique momentané que le générateur peut fournir pour démarrer les moteurs électriques Le watt de démarrage ne représente pas la puissance nécessaire pour faire fonctionner ...

Страница 21: ...a utilisée pour déterminer la période de garantie L enregistrement du produit n est pas nécessaire pour bénéficier du service de garantie sur les produits Briggs Stratton A PROPOS DE LA GARANTIE Le service de garantie est disponible uniquement par les réparateurs agréés de Briggs Stratton La plupart des réparations de garantie sont traitées automatiquement mais il peut arriver que les demandes de ...

Страница 22: ...N o t f o r R e p r o d u c t i o n ...

Страница 23: ......

Страница 24: ...ISEKI France S A S ZAC des Ribes 27 avenue des frères Montgolfier CS 20024 63178 Aubière Cedex Tél 04 73 91 93 51 E mail info iseki fr www iseki fr ...

Отзывы: