background image

Not for 

Reproduction

 5

Features and Controls

   Figure

 

1

Operation

Step 1: Safe Location

Before starting the inverter generator there are two 

equally important safety concerns regarding carbon 

monoxide  poisoning and fire that must be addressed.

Operation Location of Portable Generator to REDUCE 

THE RISK OF CARBON MONOXIDE POISONING

WARNING! 

  Engine exhaust contains carbon 

monoxide, a poisonous gas that could kill you in 

minutes. You cannot smell it, see it, or taste it. 

Even if you do not smell exhaust fumes, you could still be 

exposed to carbon monoxide gas.

•  Operate this product only outdoors far away from 

windows, doors and vents to reduce the risk of carbon 

monoxide gas from accumulating and potentially being 

drawn towards occupied spaces. 

•  Install battery-operated carbon monoxide alarms or 

plug-in carbon monoxide alarms with battery back-up 

according to the manufacturer’s instructions. Smoke 

alarms cannot detect carbon monoxide gas.

•  Do not run this product inside homes, garages, 

basements, crawlspaces, sheds, or other partially-

enclosed spaces even if  using fans or opening doors 

and windows for ventilation. Carbon monoxide can 

quickly build up in these spaces and can linger for 

hours, even after this product has shut off.

•  Always place this product downwind and point the 

engine exhaust away from occupied spaces.

If you start to feel sick, dizzy, or weak while using this 

product, get to fresh air right away. See a doctor. You 

may have carbon monoxide poisoning.

Operation Location of Portable Generator to 

REDUCE THE RISK OF FIRE 

WARNING!

   Exhaust heat/gases could ignite 

combustibles, structures or damage fuel tank 

causing a fire, resulting in death or serious injury.

•  Portable generator must be at least 1.5 m (5 ft.) from 

any structure, overhang, trees, windows, doors, any 

wall opening, shrubs, or vegetation over 30.5 cm (12 

in.) in height.

•  Do not place portable generator under a deck or 

other type of structure that may confine airflow. 

Smoke alarm(s) must be installed and maintained 

indoors according to the manufacturer’s instructions/

recommendations.

•  Carbon monoxide alarms cannot detect smoke.

•  Do not place portable generator in manner other than 

shown.

1.5 m  

(5 ft.) min.

1.5 m (5 ft.) min.

MUFFLER

Install carbon monoxide alarms inside 
your home. Without working carbon
monoxide alarms, you will not realize
you are getting sick and dying from
carbon monoxide poisoning

.

CARBON MONOXIDE ALARM(S)

USE OUTDOORS - AVOID CARBON MONOXIDE POISONING 

point away

from home

MUFFLER

MUFFLER

point away 

from home

USE OUTDOORS - AVOID CARBON MONOXIDE POISONING

CARBON MONOXIDE 

ALARM(S)

Install carbon monoxide alarms 

inside your home. Without working 

carbon monoxide alarms, you will not 

realize you are getting sick and dying 

from carbon monoxide poisoning.

A

Choke Lever

L

Parallel Operation Port

B

Side Maintenance Cover

M

Generator Reset

C

Air Cleaner (under cover)

N

QPT Switch

D

Recoil Handle

P

LED Panel

E

Oil Fill (under cover)

R

230 Volt AC Receptacle

F

Engine Switch

S

Top Maintenance Cover

G

12 Volt DC Receptacle

T

Spark Arrester Muffler

H

DC Circuit Breaker

U

Identification Label

J

Grounding Fastener

V

Fuel Cap

K

Circuit Breaker

Содержание 030698

Страница 1: ...Groupe Electrogène Notice d Utilisation 01 001557 220920 P2200 Code 030698 Retrouvez nous sur www iseki fr ...

Страница 2: ......

Страница 3: ...ll rights reserved BRIGGS STRATTON is a registered trademark of Briggs Stratton Corporation en English ar العربية bg български език cs Čeština da Dansk de Deutsch el Ελληνικά es Español et Eesti keel fi Suomi fr Français hr Hrvatski hu Magyar it Italiano lt Lietuvių k lv Latviešu nl Nederlands no Norsk pl Polski pt Português ro Română ru Pусский sk Slovenčina sl Slovenščina sv Svenska sw Kiswahili...

Страница 4: ...N o t f o r R e p r o d u c t i o n 2 BRIGGSandSTRATTON COM E D R K V F U T M H G B A C S 1 J L R 16A 13A P N ...

Страница 5: ...N o t f o r R e p r o d u c t i o n 3 2 10 B A 8 3 A 6 5 4 11 7 C B D A 9 13 12 ...

Страница 6: ... this manual is accurate and current However the manufacturer reserves the right to change alter or otherwise improve the generator and this document at any time without prior notice NOTICE If you have questions about intended use contact an authorized service dealer This equipment is designed to be used with Briggs Stratton authorized parts ONLY System Ground The generator has a system ground tha...

Страница 7: ...onoxide poisoning Operation Location of Portable Generator to REDUCE THE RISK OF FIRE WARNING Exhaust heat gases could ignite combustibles structures or damage fuel tank causing a fire resulting in death or serious injury Portable generator must be at least 1 5 m 5 ft from any structure overhang trees windows doors any wall opening shrubs or vegetation over 30 5 cm 12 in in height Do not place por...

Страница 8: ... cigarette or smoke Do not pour water on generator to put out fire Only use a extinguisher rated for flammable liquids and electrical systems such as a powder extinguisher Follow the instructions provided by fire extinguisher manufacturer before use This generator is not for use in explosive atmospheres 1 Slowly remove fuel cap 1 V to relieve pressure in tank 2 Slowly add unleaded fuel to red fuel...

Страница 9: ... circuit breaker will trip push button pops out Wait a few minutes and push the button in to reset the circuit breaker This receptacle along with the USB adapter allows you to recharge any USB powered device with a USB charging cable not included NOTICE For charging ITE Information Technology Equipment only NOTICE When using this receptacle push the QPT switch to the OFF 0 position LED Panel Figur...

Страница 10: ...ncer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Change oil while engine is warm from running as follows 1 Make sure generator is on a level surface 2 Loosen side maintenance cover screws and remove cover 3 Clean area around oil fill and remove oil fill cap 4 Tip...

Страница 11: ...ommend that you have a Briggs Stratton Authorized Service Dealer check and adjust valve clearance at recommended intervals see Maintenance Schedule Storage If storing the unit for more than 30 days use the following guidelines to prepare it for storage Change Engine Oil While engine is still warm drain oil from crankcase Refill with recommended grade See Changing Engine Oil Protect Fuel System Fue...

Страница 12: ...nk engine For all other issues see a Briggs Stratton Authorized Dealer Troubleshooting This generator is rated in accordance with Briggs Stratton 628K Starting Watts represents the momentary electrical current the generator can provide to start electric motors Starting Watts does not represent the power required to continuously run electrical loads Starting Watts is the maximum current that can mo...

Страница 13: ... initial purchase date at the time warranty service is requested the manufacturing date of the product will be used to determine the warranty period Product registration is not required to obtain warranty service on Briggs Stratton products ABOUT YOUR WARRANTY Warranty service is available only through Briggs Stratton Authorized Service Dealers Most warranty repairs are handled routinely but somet...

Страница 14: ...rer ou d améliorer le produit et ce document à tout moment et sans préavis AVIS Pour toutes questions sur l utilisation prévue contactez un revendeur autorisé Cet équipement est désigné pour être utilisé avec les pièces détachées de Briggs Stratton SEULEMENT Système de mise à la terre Le générateur dispose d un système de mise à la terre qui relie les composants du cadre du générateur aux bornes d...

Страница 15: ...au monoxyde de carbone Emplacement de fonctionnement du générateur portable pour RÉDUIRE LES RISQUES D INCENDIE AVERTISSEMENT Les émissions de chaleur gaz pourraient enflammer les produits combustibles les structures ou les réservoirs de carburant et endommager le réservoir d essence en provoquant un incendie et entraîner la mort ou de graves blessures Le générateur portable doit être disposé à au...

Страница 16: ...aleur et de toute autre source d allumage Vérifiez les durites d essence le capuchon et les joints fréquemment pour visualiser des craquelures ou des fuites Remplacez si nécessaire Ne pas allumer de cigarette ni fumer N essayez pas d éteindre le générateur en feu avec de l eau Utilisez uniquement un extincteur homologué pour feux de liquides et de systèmes électriques inflammables tel qu un extinc...

Страница 17: ...maximal disponible pour la prise de 12 Volt CC G est 60 Watts 5 A Un coupe circuit CC H protège cette prise des surcharges Si une surcharge se produit le disjoncteur se déclenche le bouton poussoir saute Attendez quelques minutes et poussez le bouton pour réinitialiser le disjoncteur Cette prise couplée de cet adaptateur USB vous permet de recharger tout dispositif alimenté par USB avec un câble d...

Страница 18: ...au au contact d huile moteur usagée Lavez les surfaces exposées avec de l eau et du savon GARDEZ HORS DE LA PORTÉE DES ENFANTS NE POLLUEZ PAS CONSERVEZ LES RESSOURCES RETOURNEZ L HUILE USAGÉE AUX CENTRES DE COLLECTE Changez l huile lorsque le moteur est encore chaud après avoir tourné de la manière suivante 1 Assurez vous que le générateur se trouve sur une surface plane 2 Desserrez deux vis du co...

Страница 19: ...e le contrôle et le réglage du jeu de soupape soit effectué par un technicien agréé Briggs Stratton aux intervalles recommandés voir Calendrier d entretien Entreposage Si vous n utilisez pas votre groupe électrogène pendant plus de 30 jours reportez vous aux indications suivantes pour le préparer au stockage Changement de l huile moteur Le moteur encore chaud vidangez l huile du carter Remplissez ...

Страница 20: ...ectez le fil à la bougie 6 Attendre 5 minutes et relancez le moteur Pour toutes autres questions voir un revendeur Briggs Stratton Diagnostic Selon la norme 628K de Briggs Stratton le watt de démarrage représente le courant électrique momentané que le générateur peut fournir pour démarrer les moteurs électriques Le watt de démarrage ne représente pas la puissance nécessaire pour faire fonctionner ...

Страница 21: ...a utilisée pour déterminer la période de garantie L enregistrement du produit n est pas nécessaire pour bénéficier du service de garantie sur les produits Briggs Stratton A PROPOS DE LA GARANTIE Le service de garantie est disponible uniquement par les réparateurs agréés de Briggs Stratton La plupart des réparations de garantie sont traitées automatiquement mais il peut arriver que les demandes de ...

Страница 22: ...N o t f o r R e p r o d u c t i o n ...

Страница 23: ......

Страница 24: ...ISEKI France S A S ZAC des Ribes 27 avenue des frères Montgolfier CS 20024 63178 Aubière Cedex Tél 04 73 91 93 51 E mail info iseki fr www iseki fr ...

Отзывы: