background image

200

-

0035

-

08

 

 

July 24 2019

 

35-DVRS31NB-2 

35-DVRS31NBN-2 

Direct Vent Gas Fireplace 

Heater 

U

SERS’  

I

NSTALLATION 

O

PERATION  and 

M

AINTENANCE 

M

ANUAL 

 INSTALLER: 

Leave this manual with the appliance

.

 

CONSUMER: 

Retain this manual for future reference.

 

-

 Do not store or use gasoline or other flammable vapors or

 

liquids in the vicinity of this or any other appliance.

 

 
-

 WHAT TO DO IF YOU SMELL GAS:

 

 

• 

Do not try to light any appliance

 

 

• 

Do not touch any electrical switch; do not use any

 

 

phone in your building

 

 

• 

Leave the building immediately

 

 

• 

Immediately call your gas supplier from a 

 

 

neighbor's phone. Follow the gas suppliers 

 

 

instructions

 

 

• 

If you can not reach your gas supplier, call the fire

 

 

department

 

-

 Installation and service must be performed by a qualified

 

installer, service agency or the gas supplier.

 

This appliance may be installed in an aftermarket 

permanently located, manufactured home (USA 

only) or mobile home, where not prohibited by 

local codes.

 

This appliance is only for use with the type 

 

of gas indicated on the rating plate. This 

appliance is not convertible for use with other 

gases, unless a certified kit is used.  

 

WARNING:

 

If the information in this manual is 

not followed exactly, a fire or explosion may 

result causing property damage, personal 

injury or loss of life.

 

SERIAL NUMBERS  312009 AND HIGHER 

Gas Fireplace Efficiency Rating

 

 

75.40%

 

 

Based on CSA P.4.1

-

15

 

Archgard Fireplace Products

 

7116 Beatty Dr

 

Mission, BC V2V 6B4

 

Canada

 

Содержание 35-DVRS31NB-2

Страница 1: ...ions If you can not reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be instal...

Страница 2: ...essures Adjusting Pilot and Convertible Pilot Orifice 22 Adjusting Primary Air 23 Contemporary Panel part list Installation Instructions 24 25 Door Removal Surround Clip Installation Surround Installa...

Страница 3: ...could become very cold to the touch Dynamic Start Advantage will solve most problems experienced by older IPI operated fireplaces Please complete and submit the warranty registration card included in...

Страница 4: ...35 DVRS31NB N 2 4 RATING PLATE...

Страница 5: ...run Terminations installed and sealed in compliance with local building code Direct vent termination is highest point in vent assembly Wiring Electrical YES IF NO WHY NOT Connected to household 110 12...

Страница 6: ...and liquids near the appliance Clothing or other flammable material should not be placed on or near the appliance WARNING Do not operate appliance with the glass front removed cracked or broken Remova...

Страница 7: ...ent National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 We recommend that our gas hearth products be installed and serviced by professi...

Страница 8: ...35 DVRS31NB N 2 8 APPLIANCE DIMENSIONS Surround Installed Surround Removed Fig 8 C Fig 8 A Fig 8 B Fig 8 D Fig 8 F Fig 8 E REAR FRONT LEFT RIGHT REAR FRONT LEFT RIGHT...

Страница 9: ...ll you must include the exterior wall insulation and termination kit Place insulation board with the foil facing in to the room as shown in figure 9 C Frame hole out opening and cut out hole for the t...

Страница 10: ...led into the wall Caulk the vent collar and fire stop from the outside to prevent cold drafts Install the termination When installing the fireplace into the wall DO NOT flush the front of the unit wit...

Страница 11: ...t using 2 ply aluminum flex a change to the 999 DV HTC is required The Brigantia 35 DVRS31NB N 2 requires 120v for the operating system There is a factory installed electrical box to accommodate the c...

Страница 12: ...iling flanges to the wall Surround depth 3 Finished Wall Fig 11 A Fig 11 B Inches mm Top to standoffs 0 0 Sides to standoffs 0 0 Adjacent Side Wall 9 227 Room Floor From bottom of fireplace shell 4 10...

Страница 13: ...on The listed chimney vent systems use a twist lock connection Assemble the vent system using the desired combination of sections and elbows for your installation Make sure you fully insert and twist...

Страница 14: ...he terminal Attach the terminal to the exterior wall using four wood screws through the holes in the corner of the vent terminal Complete the terminal installation and apply a bead of mastic around th...

Страница 15: ...RMINATION WILL CAUSE POOR COMBUSTION AND OR HIGH TEMPERTURES THAT MAY PRESENT A FIRE HAZARD WHEN HORIZONTAL VENTING 1 4 FT RISE IS REQUIRED SEE VENTING CHART FOR ACCEPTABLE VENTING CONFIGURATIONS Fire...

Страница 16: ...r 9 23 cm Note Clearances are to be in accordance with local installation codes and the requirements of the gas supplier G Do not install above a meter regulator assembly within 3 feet 90 cm horizonta...

Страница 17: ...llations For vertical installations determine the length of vent pipe required by meas uring the distance from the appliance flue outlet to the ceiling the ceiling thickness the vertical rise in the a...

Страница 18: ...protection Pitch Rise in ft Rise m 0 12 6 12 12 1ft 30m 7 12 9 12 18 1 5ft 46m 10 12 12 12 24 2ft 61m 13 12 16 12 36 3ft 91m 17 12 24 12 48 4ft 1 22m Fig 18 A When passing through a flat ceiling inst...

Страница 19: ...mitted 3 Note if more than 1 90 elbow is used horizontally the maximum horizontal is reduced by 1ft Example B If to reach the desired termination at point B you use 2 90 elbows you would be required t...

Страница 20: ...SIT Control Module is powered by 120V with an internal transformer for the valve This is pre wired to the factory installed electrical box for the electrician Some jurisdictions may require you insta...

Страница 21: ...ndividual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to do so will damage the appliance s gas val...

Страница 22: ...plate 6 Be sure to tighten the set screw inside the tap after you have finished taking pressure readings 7 Check for leaks CHECKING INLET AND OUTLET GAS PRESSURE CHECKING AND ADJUSTING PILOT The flame...

Страница 23: ...ide the air shutter toward the left side of the appliance Retighten the wingnut To close the air shutter and decrease air flow to the burner loosen the wingnut and slide the air shutter toward the rig...

Страница 24: ...35 DVRS31NB N 2 24 Contemporary Panels ITEM NO PART NUMBER DESCRIPTION QTY 1 311 6351 FB REAR PANEL 1 2 311 6352 FB SIDE PANEL 2 L R 3 750 1015 BAFFLE 1 Fig 23 A PANELS DETAIL Fig 23 B 1 Back Side...

Страница 25: ...the right to make room for the side panel Install keyed side panel to the left side same as right side Remove burner cover and place to the side to be re installed at the end After the panels have be...

Страница 26: ...om out to 30 degrees and lift upward to release the 2 latches at the top of the door CAUTION Beware the glass does not drop out Firmly grip the door and glass when removing door assembly Surround Clip...

Страница 27: ...lation Optional Your Brigantia Fireplace is approved for use with the Optional Silhouette Log Set The logs come in White Black and Grey Each set comes with 2 logs and you can install a max of 4 logs i...

Страница 28: ...35 DVRS31NB N 2 28...

Страница 29: ...35 DVRS31NB N 2 29 LIGHTING INSTRUCTIONS ON RATING PLATE...

Страница 30: ...replace you build a fire You start with a little bit of tinder and kindling to create small fire and then work your way up to larger logs once a draft has been established Dynamic Start uses the same...

Страница 31: ...e provisions for ade quate combustion and ventilation air A T T E N T I O N If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or lo...

Страница 32: ...ovided to index between the features and a Thermostat Key is used for on off or to index through the thermostat func tion Additionally a Key Lock function is provided A T T E N T I O N TURN OFF THE MA...

Страница 33: ...I N G THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCY DEVICES PLACING THE TRANSMITTER IN OR NEAR METAL ENCLOSURES MAY REDUCE THE SIGNAL RANGE HANDHELD REMOTE DISPLAY Not for use on this unit OPTIONAL...

Страница 34: ...ll activate the appliance A single beep from the receiver will confirm reception of the command TURN OFF THE APPLIANCE With the system OFF press the ON OFF Key on the Transmitter The Transmitter displ...

Страница 35: ...ne step Repeat to lower the flame till OFF The UP Arrow Key will increase the flame height each time it is pressed If the UP Arrow Key is pressed while the system is on but the flame is off the flame...

Страница 36: ...will change to show that the room thermostat is ON and the set temperature is now active To adjust the temperature press the Up Down Arrow Keys until the desired temperature is displayed SMART THERMOS...

Страница 37: ...ontrol display Replace batteries Battery Back up Red LED indicator will enter a 1 blink sequence IFC Module will emit a double beep when it receives an ON OFF command from the hand held remote Replace...

Страница 38: ...all battery power is lost When the batteries are replaced this Icon will disappear REMOTE CONTROL SETUP AND OPERATION BACKUP BATTERY PACK used when electrical power is interrupted Red LED indicator on...

Страница 39: ...IPI Main Burner does not light Electrical power interrupted or disconnected Restore power to fireplace Replace batteries if depleted Use Battery Back up Remote not working properly Check Batteries rep...

Страница 40: ...e Check venting Gas pressure too high Compensate for altitude if required Improper venting set up insufficient rise on vent Small sharp flame Blue color Improper venturi setting of primary air Pilot B...

Страница 41: ...not obstructed and it is recommended you use a vacuum cleaner to clean off any dust or lint Vacuum and clean any lint accumulations or debris in the firebox on the burners on the pilot at the primary...

Страница 42: ...so the red side propane with the hole in it is showing Tighten the pilot hood back up so that it is lined up with the two probes on both sides of the pilot assembly F O R Y O U R S A F E T Y SHUT OFF...

Страница 43: ...rn on the gas and electrical supplies and check for leaks at all connections Turn on the fireplace so the burner is on Test inlet and outlet pressure Visually check pilot flame Flame should envelope t...

Страница 44: ...305 2080 Fuse 3 15A 250V pack of 5 301 0068 35 Orifice Main Burner Orifice Drill to 35 DMS for Natural Gas EA 301 0068 52 Orifice Main Burner Orifice Drill to 52 DMS for LP Gas EA 308 0123 Pilot Assem...

Страница 45: ...re your fireplace will expand and contract at differ ent rates when your fireplace is on and will continued as your fireplace completes its heating func tion You will likely hear these same sounds mor...

Страница 46: ...id if work is carried out by an unqualified person s Only original Brigantia parts may be used Please consult your Brigantia dealer or representative if in doubt about a replacement part s OBTAINING W...

Страница 47: ...Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this warranty card mm dd yyyy POSTAGE FOLD DOWN AT LINE FOLD DOWN AT LINE T...

Страница 48: ...ARCHGARD FIREPLACES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...