TIME SERVER CONNECTION STATUS
After the console has connected to the internet, it
will attempt to connect to the internet time server to
obtain the UTC time. Once the connection succeeds
and the console's time has been updated, the “
” icon will appear on the LCD.
ADVANCE SETTING IN WEB INTERFACE
Press
"ADVANCED"
key at the top of web interface to enter the advance setting page, this
page allow you to set and view the calibration data of the console, as well as update the
firmware version on PC web browser.
Upload
Browse
Firmware version: 1.00
-560~ 560hpa / -16.54 ~ 16.54inHg / -420 ~ 420mmHg
Setting Range:
Temperature
o
C
Outdoor
Indoor
CH 1
CH 2
CH 3
CH 4
CH 5
CH 6
CH 7
Humidity %
Relative Pressure Offset:
Absolute Pressure Offset:
hpa
Range: -20 ~ 20
(Default: 0.0)
Current offset: 10
Current offset: -9
Current offset: -5
Current offset: 2
Current offset: -2
Current offset: 3
Current offset: -2
Current offset: 1.2
Current offset: -5
Current offset: -0.2
Current offset: -3
Current offset: -20.1
Current offset: -10
Current offset: 11.5
Current offset: -3
Current offset: -3
(Default: 0)
Current offset: 10
(Default: 0)
Current offset: 0.2
Current offset: -5
Current offset: 1
Pressure
Range: -20.0 ~ 20.0
o
C
-36.0 ~ 36.0
o
F (Default: 0.0)
*UV gain:
Range: 0.01 ~ 10(Default: 1.00)
Current gain: 1.1
*Light gain:
Range: 0.01 ~ 10(Default: 1.00)
Current gain: 1.1
* Depends on the model
*Wind speed gain:
*Wind direction:
*Rain gain:
Range: 0.5 ~ 1.5(Default: 1.00)
Range: -10 ~ 10(Default: 0
o
)
Range: 0.5 ~ 1.5(Default: 1.00)
Current gain: 0.85
Current offset: 2
o
Current gain: 0.75
SETUP
ADVANCED
Select setting unit
Press "SETUP" icon to
Setup page
Outdoor and Ch
1~7 temperature
calibration section
Pressure calibration
section
Current firmware
version
The firmware update
function only available
in PC web browser
ADVANCED page
Select setting unit
The rain, wind speed, UV and Light
calibration use gain method. The
wind direction is +/- 10 offset.
Outdoor and Ch 1~7 humidity
calibration section
Current offset value is the value
that you set before to offset the
pressure reading.
CALIBRATION
1. User can input the offset and/or gain values for different parameters while current
offset and gain values are shown next to their corresponding blank.
2. Once completed, press
Apply
at the bottom of the SETUP page
The current offset value will show the previous value that you entered, please input
the new value in the blank if any changes needed, the new value will effective once you
press
Apply
icon in SETUP page.