27
Out temperature reading too
high in the day time
Make certain that the sensor array is not too close to
heat generating sources or structures, such as buildings,
pavement, walls or air conditioning units.
Some condensation beneath
the UV sensor may occur
overnight
This will disappear when temperature rises up under the sun
and will not affect the performance of the unit.
No WI-FI connection
1. Check for WI-FI symbol on the display, it should be alway on.
2. Make sure you connect to 2.4G band but not 5G band of
your WI-FI router.
Temperature or humidity not
accurate
1. Do not place your console or sensor close to the heat source
2.
If the sensor still not accurate adjust the value in calibration
mode.
9. SPECIFICATIONS
9.1 CONSOLE
General Specification
Dimensions (W x H x D)
130 x 112 x 27.5mm (5.1 x 4.4 x 1.1 in)
Weight
220g (with batteries)
Main power
DC 5V, 1A adaptor
Backup battery
CR2032
Operating temperature range
-5˚C ~ 50˚C
Operating Humidity range
10~90% RH
Support sensors
-1 Wireless 7-in-1 sensor (included)
-Support Up to 3 Wireless Thermo-hygro sensors (optional)
RF frequency
868Mhz (EU or UK version)
Time Related Function Specification
Time display
HH: MM
Hour format
12hr AM / PM or 24 hr
Date display
DD / MM or MM / DD
Time synchronize method
Through the server to get the local time of the console location
Weekday languages
EN / DE / FR / ES / IT / NL / RU
BAROMETER
Barometer unit
hPa, inHg and mmHg
Accuracy
(700 ~ 1100hPa ± 5hPa) / (540 ~ 696hPa ± 8hPa) (20.67
~ 32.48inHg ± 0.15inHg) / (15.95 ~ 20.55inHg ± 0.24inHg)
(525 ~ 825mmHg ± 3.8mmHg) / (405 ~ 522mmHg ± 6mmHg)
Typical at 25°C (77°F)
Resolution
1 hPa / inHg is 2 decimal place / mmHg is 1 decimal place
In Temperature
Temperature unit
°C and °F
Accuracy
<0°C or >40°C ± 2°C (<32°F or >104°F ± 3.6°F)
0~40°C ±1°C (32~104°F ± 1.8°F)
Resolution
°C / °F (1 decimal place)
In Humidity
Humidity unit
%