Страница 1: ...Carrier Class AirMax BaseStation Models M2 M5 Titanium ...

Страница 2: ......

Страница 3: ... Carrier Class AirMax BaseStation Models M2 M5 Titanium GPS Patch Antenna RF Cables Qty 2 Quick Start Guide Installation Requirements GPS antenna needs to have clear line of sight to the sky Shielded Category 5 or above cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the PoE We recommend that you protect your networks from the most brutal e...

Страница 4: ... Cover Secondary AUX Ethernet Port Primary MAIN Ethernet Port LEDs Main The first Ethernet LED will light steady green when an active Ethernet connection is made to the Primary Ethernet Port and flash when there is activity Aux The second Ethernet LED will light steady green when an active Ethernet connection is made to the Secondary Ethernet Port ...

Страница 5: ... Dish or Sector Antenna The cable connections are the same for either antenna type 1 Press on both sides of the Removable Cover to slide it off 2 Connect an Ethernet cable to the Primary Ethernet port on the Rocket Titanium 3 Connect the GPS Patch Antenna to the center SMA connector on the Rocket Titanium ...

Страница 6: ...onnector with Rubber Shroud Note The connectors with the rubber shroud should not be connected on the inside of the Rocket Titanium 5 Reconnect the Removable Cover 6 Connect the Rocket Titanium to the Antenna 7 Connect the other ends of the RF cables with the rubber shroud to the SMA connectors on the Antenna Connecting to a Sector Antenna Connecting to a Dish Antenna ...

Страница 7: ...g the Rocket Titanium 8 Place the magnetic GPS Patch Antenna on the pole mounting bracket Recommended Placement of GPS Patch Antenna on a Dish Antenna Recommended Placement of GPS Patch Antenna on a Sector Antenna ...

Страница 8: ...ket Titanium to the Ethernet port labeled POE on the PoE Adapter 10 Connect an Ethernet cable from your LAN to the Ethernet port labeled LAN on the PoE Adapter 11 Connect the power cord to the power port on the PoE Adapter Connect the other end of the power cord to a power outlet ...

Страница 9: ...c IP address on the 192 168 1 x subnet 3 Launch your Web browser and type http 192 168 1 20 in the address field and press enter PC or return Mac 4 The login screen will appear Enter ubnt in the Username and Password fields Select your Country and Language You must agree to the Terms of Use to use the product Click Login Note U S product versions are locked to the U S Country Code to ensure compli...

Страница 10: ...n the Main tab you can verify the GPS Signal Quality Click on the GPS Details tab under Monitor to view the Satellite and Signal details GPS Details tab The AirOS Interface will allow you to customize your settings as needed ...

Страница 11: ...vice is operated within local country regulatory requirements Since Ubiquiti Networks equipment can be paired with a variety of antennas and cables the Antenna Gain Cable Loss and Output Power fields are provided to the professional installer to assist in meeting regulatory requirements Note U S product versions are locked to the U S Country Code to ensure compliance with FCC regulations ...

Страница 12: ...h other Additionally some RF bands like 900 MHz and 3 65 GHz have only 1 20 MHz channel requiring all the basestations to use the same frequency This interference will cause Receive Rx errors on the basestation when it receives packets from associated stations that are typically miles away With AirSync the basestations make use of a common clock source using the built in GPS receiver One device is...

Страница 13: ...erface see page 7 for login details 2 Go to the Ubiquiti tab 3 Select the appropriate mode Master Mode should be selected on your master device and Slave Mode should be selected on all of your slave devices with the MAC address of the Master in the Sync Master field 4 Click Change to save your selection ...

Страница 14: ...oE Supply Included Power Method PoE 48V injector or using PoE 802 3af capable Ethernet switch uses all data pairs for power auto polarity correction Operating Temperature 30 to 75 C Operating Frequency M2 2402 2462 MHz M5 5170 5875 MHz Networking Interface 2 10 100 1000BASE TX Ethernet Ports Only 5725 5850 MHz supported in the USA ...

Страница 15: ...e hazard if the limitations are not followed 2 There are no operator serviceable parts inside this equipment Service should be provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided appro...

Страница 16: ...hout obtaining a Return Materials Authorization RMA number from UBIQUITI NETWORKS Products returned without an RMA number will not be processed and will be returned to Buyer freight collect UBIQUITI NETWORKS shall have no obligation to make repairs or replacement necessitated by catastrophe fault negligence misuse abuse or accident by Buyer Buyer s customers or any other parties The warranty perio...

Страница 17: ...ot installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense RF Exposure Warning The transceiver described here emits radio frequency energy Although the power leve...

Страница 18: ...nt English European Directive 2002 96 EC requires that the equipment bearing this symbol on the product and or its packaging must not be disposed of with unsorted municipal waste The symbol indicates that this product should be disposed of separately from regular household waste streams It is your responsibility to dispose of this and other electric and electronic equipment via designated collecti...

Страница 19: ...e recogida y eliminación de residuos de su zona o pregunte en la tienda donde adquirió el producto Français La directive européenne 2002 96 CE exige que l équipement sur lequel est apposé ce symbole sur le produit et ou son emballage ne soit pas jeté avec les autres ordures ménagères Ce symbole indique que le produit doit être éliminé dans un circuit distinct de celui pour les déchets des ménages ...

Страница 20: ... ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele Suomi Finnish UBIQUITI NETWORKS vakuuttaa täten että UBIQUITI NETWORKS device tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen Français French Par la présente UBIQUITI NETWORKS déclare que l appareil UBIQUITI NETWORKS device est conforme aux exigences essent...

Страница 21: ...orma mal ti ijiet essenzjali u ma provvedimenti o rajn relevanti li hemm fid Dirrettiva 1999 5 EC Norsk Norwegian UBIQUITI NETWORKS erklærer herved at utstyret UBIQUITI NETWORKS device er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999 5 EF Slovensky Slovak UBIQUITI NETWORKS t mto vyhlasuje e UBIQUITI NETWORKS device sp a základné po iadavky a v etky príslu né ustanove...

Страница 22: ...proteja sus redes de los entornos más hostiles y los devastadores efectos de las descargas electrostáticas utilizando cable Ethernet blindado con calidad industrial de Ubiquiti Networks Para obtener más información visite www ubnt com toughcable Français Nous vous recommandons de protéger vos réseaux contre les environnements les plus brutaux et les décharges électrostatiques les plus dévastatrice...

Страница 23: ......

Страница 24: ...Phone 9 a m 5 p m PST 408 942 1153 Online Resources Wiki Page www ubnt com wiki Support Forum www ubnt com forum Knowledge Base www ubnt com kb Downloads www ubnt com support downloads w w w u b n t c o m 2011 Ubiquiti Networks Inc All rights reserved ...

Отзывы: