67XXU USB/Serial Scale Service Manual
45
COM2
(9 Pin)
BUD.RT
1200
9600
Select COM2 baud rate
2400
4800
9600
19200
38400
BT.FMT
8N1
7e1
Select COM2 byte format
(1) 8N1=8 data bits, No parity check
bit, 1 stop bit
7O1
(2) 7O1=7 data bits, 1 Odd parity
check bit, 1 stop bit
7E1
(3) 7E1=7 data bits, 1 Even parity
check bit, 1 stop bit
OUT.MD
none
PRT.CD
Select COM2 output mode
(1) NONE=no communication
CONT
(2) CONT=continuously output
(3) PRINT=output after PRINT key
pressed
CMD
(4) CMD=output after a request
command is received
PRT.CD
(5) PRT.CD= output after PRINT
key pressed or request command
received
STABL
(6) STABL=output after scale is
stable; Note: use PRINT or CMD to
output data, the scale must be
stable
st.nld
**
(7) ST.NLD=output after scale has
returned to zero range and is
stable. (OTHER>NLD.RG)
nld
**
(8) NLD= Output after scale has
returned to zero range and does not
wait for the scale to be stable.
(OTHER>NLD.RG)
Pr.nLD
(9) PR.NLD= Manual push button
print once after scale is stable.
Scale has to return to zero range
(OTHER>NLD.RG) before another
push button print command can be
executed.
**
Note: If PRINT, STABL, ST.NLD, LNLD or CMD are used to output data, the scale must be stable.
USER
SubMenu1 SubMenu2
Option
Default
Parameter Description
Comment