67XXU USB/Serial Scale Service Manual
29
4.3.10 Check Weight (compare feature)
To make the weight compare function available, set CONFG-FUNC-COMPAR item to
YES (refer to Chapter
for details on entering and navigating the setup mode). The
high and low limitation of weight should be set correctly according to following steps:
1.
In weighing mode or count mode, press the
[UNIT]
key more than 3 seconds to
compare the high and low data.
1a.
If in the weigh mode and the
COMP
parameter is accessed,
unt.lb
or
unt.kg
will
be displayed when in the weigh mode. Use the
[UNIT]
key to change the
active unit.
1b.
If in the count mode, go to step
.
2.
Use the
[TARE]
key access the high value.
high
and then
L0000
will be
displayed.
3.
Use the
[UNIT]
and
[HOLD]
keys to enter the high value. Note: The
[UNIT]
key changes the flashing digit. The
[HOLD]
key goes to the next digit.
4.
Press the
[TARE]
key to confirm the entry.
5.
After
Low
is accessed,
L0000
will be displayed. Use the
[HOLD]
and
[UNIT]
keys to input the low number.
6.
Press the
[TARE]
key to confirm.
6a.
After a reasonable limitation is set and compare is active, one of annunciators
OK will be illuminated. The beeper will sound according to its setting in USER-
BEEP.
7.
Press the
[ZERO]
key to exit the
Comp
mode.
4.4 Navigating the Count Mode
In this mode, the scale will weigh goods, calculate and display its counts after the piece
weight of the goods is obtained. The count function must be enabled in the setup mode.
The CONFG-FUNC-COUNT item should be set to YES in CONFIG menu. Refer to
Chapter
for details on entering and navigating the setup mode.
4.4.1 Enter Count Mode
1.
To enter counting mode press the
[HOLD]
+ [UNIT]
keys for more than 3
seconds.
WEIGH
will be displayed.
2.
Use the
[UNIT]
key to select
COUNT
.
3.
Press
[TARE]
to confirm the parts counting mode. The PCS annunciator will
be illuminated.
3a.
In counting mode, the function of
[ZERO]
,
[TARE]
,
[PRINT]
,
[ON/OFF]
and
[HOLD]
keys are available.
NOTE: If the High number value is 0 or is equal or less than low number, the
comparison will be disabled, and the input data has no limitation.