FLOW-TEK SERIES 19L SEGMENTED BALL VALVE
Installation, Operation, and Maintenance Manual
20 of 31
© 2021 BRAY INTERNATIONAL, INC. ALL RIGHTS RESERVED. BRAY.COM The Information
contained herein shall not be copied, transferred, conveyed, or displayed in any manner that would
violate its proprietary nature without the express written permission of Bray International, Inc.
12.0 REMOVING VALVE FROM PIPELINE
12.1
If an internal problem is suspected with the valve and disassembly
is required, remove the valve from the pipeline by proceeding as
follows.
WARNING
Depressurize line to atmospheric pressure, drain all process fluids
and decontaminate the valve (if caustic or hazardous materials
are present). Failure to do so can cause serious injury.
Make sure the valve is in closed position.
12.2
Neutralize all energy (electrical, pressure and mechanical)
sources.
12.3
Attach a hoist or some means to support the valve.
12.4
Remove line bolting.
CAUTION
Do not attempt to pry line flanges apart by pushing or pulling on
the valve or actuator.
12.5
Slide the valve carefully from the pipeline.
CAUTION
To avoid damage to the gasket surfaces, do not twist the valve.
12.6
After the valve is completely removed from the line, slowly relieve
actuating medium pressure from the actuator.
WARNING
Ensure hands and/or any other items are removed from the bore
of the valve.