FLOW-TEK SERIES 19L SEGMENTED BALL VALVE
Installation, Operation, and Maintenance Manual
19 of 31
© 2021 BRAY INTERNATIONAL, INC. ALL RIGHTS RESERVED. BRAY.COM The Information
contained herein shall not be copied, transferred, conveyed, or displayed in any manner that would
violate its proprietary nature without the express written permission of Bray International, Inc.
11.0
ACTUATOR REMOVAL AND REMOUNTING
11.1
Removing Actuator
11.1.1 Refer to relevant actuator installation, operation, and
maintenance instructions before proceeding.
11.1.2 Neutralize all energy sources (electrical, pressure and
mechanical).
11.1.3 Support the actuator assembly before disconnecting it from the
body assembly.
11.1.4 Unbolt the actuator assembly from valve mounting bracket.
11.1.5 Lift actuator assembly off stem.
11.2
Remounting Actuator
11.2.1 Before mounting an actuator on the valve body, verify that the
segment rotation matches the actuator rotation and complies
with the actuator failure mode requirements.
11.2.2 Bolt the bracket onto the body (if it has been removed.)
11.2.3 Slide the entire actuator assembly onto the stem.
11.2.4 Bolt actuator assembly to valve mounting bracket.
11.2.5 Verify and set actuator stops..
NOTICE
Refer to the actuator IOM for necessary adjustments.