14
Before Each Use – Inspection/Maintenance
Step One: Inspect and maintain log splitter before each use
If the log splitter has been used previously, it must be inspected and maintained BEFORE EACH SUBSEQUENT USE.
WARNING
ALWAYS shut off the engine, disconnect the spark plug, and relieve system pressure before
inspecting, cleaning, adjusting, or repairing the splitter. Relieve system pressure by moving Split
Control Lever back and forth several times.
IMPORTANT:
If a part needs replacement, only use parts that meet the manufacturer's specifications. Replacement parts that do not meet
specifications may result in a safety hazard or poor operation of the log splitter.
1. Engine Off /
Relieve Pressure
Perform all inspections/repairs with the engine off and hydraulic system pressure relieved.
1.
Make sure engine is off and cool.
2.
Disconnect the spark plug.
3.
Relieve all hydraulic system pressure by moving the Split Control Lever back and forth
several times.
2. Remove Debris
Remove debris from engine, muffler, and moving parts.
1.
Engine debris:
Debris on a hot engine can be a fire hazard. Clean debris and chaff from
engine cylinder head, cylinder head fins, fan housing/recoil starter, and muffler areas.
Avoid contact with hot muffler.
2.
Other debris: Debris on moving parts can cause excess wear. Clear debris from the
beam, wedge, log dislodger, and endplate.
3. Fuel Tank / Lines Check fuel tank and fuel lines for leaks.
Any fuel leak is a fire hazard. Fix any fuel leaks before starting engine.
4. Mechanical Parts Check to be sure that all nuts and bolts are tight
to ensure the log splitter is in safe working
condition.
Apply grease to the top of the beam
and underneath the edge of the beam,
where the wear pads travel.
Содержание VH1724GC
Страница 2: ...2 Hazard Signal Word Definitions ...
Страница 30: ...30 Parts Breakdown Exploded View Rev A ...
Страница 59: ...59 This page is intentionally left blank ...
Страница 62: ...62 20195 S Diamond Lake Rd Ste 100 Rogers MN 55374 1 800 350 8739 ...