3) PTO relay and PTO indicator: The PTO relay coil power is supplied through the wiring 0.5YG or 0.5LY
PTO relay and PTO indicator: The PTO relay coil power is supplied through the wiring 0.5YG or 0.5LY
PTO relay and PTO indicator: The PTO relay coil power is supplied through the wiring 0.5YG or 0.5LY
depending on the position of the PTO selection switch. The main power of the PTO relay is connected
to the ignition switch ON power passed through the 10 A fuse. The main power of the PTO relay is
sent through the wiring 0.85YL. It is sent to the instrument cluster through the connecting wiring (E) to
inform the driver with the PTO operation status before it reaches the PTO valve. Therefore, the PTO
indicator on the instrument cluster can be turned on properly even when the PTO is not operated due
to malfunction of the PTO valve. Also, when the PTO selection switch is set in the LIN� position, the
PTO indicator on the instrument cluster goes off even though the PTO is turned off only temporarily by
operation of the driving clutch pedal or lift arm lever. Make sure to maintain high standards of safety in
this condition.