03-9940.185
3 - used to display the current temperature with accuracy to one decimal place °C, °F
(when the temperature is displayed the corresponding unit symbol - ° C, ° F - is lit)
- Displaying the external sensor temperature together with the OUT symbol
- Displaying selected parameters (M01 – M23),
- Particular pre-selections (PR 1-7; PRA),
- Displaying possible errors (E 00-99).
4
The pre-selection symbol – is lit when at least one pre-selection is activated
5
The alarm clock symbol – is lit when the alarm clock is activated
6
The external key symbol, Radio module or GSM module – is lit when the heater is
turned on using the external key, Radio module or GSM module.
7
The temperature sensor in the timer symbol of activation
8
The glow symbol - is lit during start, cooling down and combustion chamber burning
9
The activation of the external temperature sensor symbol
10
The heating symbol – flashes while the heater is turned on and during generating
(when burning at T), it is lit when the heater is turned on successfully
11
The °C, °F symbol shows the current temperature,
- Together with the OUT symbol it displays the temperature of the external sensor,
when the operator presses the
key and the sensor is connected. When no external
sensor is connected, - - - is displayed
12
The OUT symbol - is lit together with the temperature data of the external sensor, when
the operator presses the
key and the sensor is connected. When no external
sensor is connected, - - - is displayed. If the timer is active, it cannot be displayed the
temperature of the external sensor.
13
The ventilation symbol – is lit during ventilation and ventilation of the combustion
chamber, it flashes during the cooling down cycle of the heater
14
bar graph
- in the power based heating or ventilation mode, shows the set heating power or that of
the ventilator in 10 steps (minimum power is displayed by a single dash, while at
maximum power all the dashes are displayed)
- in the temperature based heating mode, the bar graph shows the relative value in 10
steps from 1 ° to 30 ° C (33.8 ° F to 86 ° F,) the exact temperature will be displayed
when the desired temperature is set
15
The symbol appears if the time is set to the 12-hour format
2.3
CONNECTORS
Communication connector (3pin) is used to connect the heater. When using a wye, an external temperature
sensor and "other equipment can be connected via the LIN-bus.
The key connector and backlight (2-pin socket) allows permanent timer shutdown when the motor is running
and permanent backlight when the lights are turned on. A look inside the connector - fuse on top - left pin
backlight / right timer. It is necessary to set the correct grounding polarity.