18
03-9940.185
5.
COMBUSTION CHAMBER BURNING
Triggered by pushing and holding the
key in the sleep mode (only in the setting of power mode), the
burning is signaled by a simultaneous flashing of the yellow and green LED. It is used when heating fails to
start, i.e. glows and ventilates moderately without further fuel supply. When the burner is ignited successfully,
MC settings will be used. The process can be turned off by pressing the
key again and is time limited.
6. REFUELING
Refueling takes place when the fuel line needs refilling and can be set up using the MENU - see point 8
.
7. TIMER
The timer is used to restrict the required time period of heating when the ignition key is turned off. The time is
adjusted to 30 minutes and cannot be changed. After this time, the heater is turned off automatically and cools
down. By turning on the key in the ignition, the timer restriction is cancelled and heating can resume. The timer
mode is indicated by the yellow LED. The timer mode can be canceled by turning on the ignition key or
pressing the
key for approx. two seconds – the yellow LED goes out. If the heater is on, turning off the
ignition key always activates the timer. When active the timer, not possible to display the temperature sensor
T3.
The ventilation mode is restricted to 6 hours by the timer and cannot be shut down.
8. MENU
Entering the MENU: Press and hold the
key, when the green LED flashes press the
button
simultaneously.
Green or yellow LED starts to flash depending on the heating mode - gap1x flash.
MENU controls: Confirm and go to the next step in the MENU - press the
key
Selection in the Menu - turn the potentiometer
Confirm and exit the MENU - press the
key
After approx. 50 sec. of inactivity, MC goes into operation mode.
MENU features: 1. Gap1x flash - Switch: Heating in the power mode (green LED)
Heating in the temperature mode (yellow LED)
2. Gap 2x flash - Selection of the temperature sensor:
T1 - sensor in the heater (green LED)
T2 - sensor in the MC/Timer (yellow LED)
T3 - external sensor (red LED)
3. Backlight only - backlight settings - in this step it is possible to adjust 5 levels of
intensity by the potentiometer
4. Gap 3x flash - Selecting grounding of the site:
+ (red LED)
- (green LED)
5. Nothing is lit – Pumping is functional
In this step, the pumping with a frequency 6Hz for a maximum of 600sis activated by
turning the potentiometer (indicated by alternating flashing of the yellow and green
LED). Pumping can be terminated by turning the potentiometer, which stops flashing.