24
03-9940.185
Functional sensors displayed:
T1 sensor in the heater
T2 sensor in the timer (factory settings T2)
T3 is displayed and can be selected only if connected to the LIN-bus
M05: Selecting the heating mode
P/T (factory settings P)
M06: Defining the character set
En/CS (factory settings En)
M07: Setting the temperature unit
°F/°C (factory settings °C)
M08: Checking the power supply
M09: Setting backlight intensity
Backlight of the keys (symbol bL) can be set from 0 to 9 by using the
and
keys (factory
settings bL4, r9, G9, b9)
LCD backlight can be set from 0 to 9 by using the
and
keys for each colour separately (red -
symbol "r", green - symbol "G", blue - symbol "b"). To confirm and switch to another submenu press the
key (factory settings bL4, r9, G9, b9)
M10: Reset to factory settings
Presets and alarm settings are canceled while the polarity of the network and time settings are not
changed. Clocks revert to the 24 hour format. Reset can only be done when the heater is inactive
.
8.
SERVICE MENU
Entering the MENU is not possible if an error is reported.
Enter the service MENU:
Go to the M11 (PIN) position only from position M10 by using the
key. When using the
key in the
MENU, the M11 position is skipped (i.e. going from M01 to M10).
By pressing
0-0-0 appears on the display.
Enter the PIN using the
keys and confirm your selection
After the PIN is entered successfully next menu items spanning from M11 to M23 will appear.
M11: Polarity of inputs (POL)
Changing the polarity of inputs (i.e. when Light and Ignition inputs respond to + or - polarity)
M12: Pump (Pu)
Starts the pump in the time set (default: 150 s)
Pumping time can be adjusted incrementally by 10s using the
keys to max. 600 seconds
Turning the pump ON/ OFF is possible at any time using the
key
M13: The serial number of the main unit (CU)
The CU serial number („Control Unit“) can be displayed by using the
keys
M14: The serial number of the heater (MU)
The heater serial number („Main Unit“) can be displayed by using the
keys
M15: The motor speed (Mot)
The main display shows the current motor speed.
Only 3 digits are displayed, the figure is given in revolutions per minute (x10 / 1min).
M16: Pump frequency (PFr)
The main display shows the pump frequency.
The figure is shown in Hz with accuracy to one decimal place (max. 99.9 Hz)