19
03-9940.185
9. ERROR REPORT
If the heater detects an error– the red LED is flashing. The type of error is shown by the number of flashes
between the gaps as shown in the table below. The error is displayed until the operator intervenes (press any
key to remove the error message). If the initial cause of the fault persists (heater repeatedly sends an error
message) the red LED will continue to flash. The red LED flashes only when the heater sends an error code or
is cooling down (ventilates).
ALFA TIMER
BREEZE IV - WIND IV – ATESO air heater control
1. FEATURES
The timer of the BREEZE IV, WIND IV and ATESO ALFA air heater is used to turn on / off the heating and
ventilation. In the heating mode, controls can be used to change the heating power or desired temperature, in
the ventilation mode the fan speed can be changed.
Package Contents:
♣
Controls
1 pc
♣
Cable
2 pcs
♣
Velcro
2 pcs
♣
Plastic clip
1 pc
♣
Screw for fastening the clip
1 pc
The heater can operate in the following modes:
-
Power based heating
-
Temperature based heating
-
Ventilation
-
Combustion chamber burning
-
MENU user
-
MENU service
MC errors –
number of
flashes
Corresponding
errors Timer/
Monitor:
Description
2.
1,2
Low voltage, overvoltage
3.
12,13
Failed start, flame extinction
4.
14,16
Failed cooling down process, high intake air temperature,
5.
5,6,60,82
Plug error,
total current overload CU
6.
3,4,30
Pump error, wrong pump, blown overheating fuse
7.
7,8,9,81,64
Motor error
8.
70,74, 75, 79
Flame sensor error, chamber overheating, timer sensor error,
external sensor error, auto ignition,
9.
others
Other