2
Express® Lavatory System SS-Series
SS-3/BIR/WH97TAS
Installation - Obsolete
4/24/08
Bradley Corporation • 215-1469 Rev. B; EN 08-805
Pre-Installation Information
Barrier-free and ADA compliant - standard height mounting
The SS-3/BIR/WH97TAS Express® Lavatory System must have a rim height of 34" above finished
floor to be compliant with Americans with Disabilities Act (ADA). When mounted at 34" rim
height, the Express® meets ADA, ANSI and UFAS requirements for barrier-free clearances,
reaches and controls. Always check local codes and ordinances for compliance.
Barrier-free and ADA compliant - juvenile height mounting
The SS-3/BIR/WH97TAS Express® Lavatory System must have a rim height no higher than 31"
above finished floor to be compliant with Americans with Disabilities Act (ADA) Accessibility
Guidelines for Buildings and Facilities: Building Elements Designed for Children's Use; Final
Rule.
Infrared sensor and control box
Each sprayhead is controlled by a separate sensor and single-operation control box, enabling each
user to activate a single flow of water. Each valve uses less than half the maximum of hot water
allowed by the ANSI/ASHRAE/IESNA 90.1-1989-Standard.
Supplies required for installation:
• (10) 3/8" wall anchors, bolts and washers to mount frame and bowl (minimum
pull-out rating of 1,000 lbs.) and bowl to wall
• 1/2" NPT tempered supply piping
• 1-1/2" NPT drain piping
• (18) “AA” alkaline batteries