10
Express® Lavatory System SS-Series
SS-3/BIR/WH97TAS
Installation - Obsolete
4/24/08
Bradley Corporation • 215-1469 Rev. B; EN 08-805
Figure 8
Figure 7b
Installation Instructions continued . . .
Step 4: Connecting supply and drain
1. FOR HOT AND COLD SUPPLY: Using a thread sealer, thread the stop/strainer check valve
onto the hot and cold wall stub-outs. (see Figure 7a). Using the thread sealer, attach the male
end of the 1/2" flexible hose to the Vernatherm™ valve (one hose on the hot side, the other
hose on the cold side) (see Figure 7a). Attach the female swivel end to the stop/strainer check
valve (located on the wall stub-out) using the fiber washer attached to the hose.
NOTE: The red marking on Vernatherm™ Mixing Valve indicates hot water supply inlet.
FOR SINGLE TEMPERED SUPPLY: Using a thread sealer, thread the 1/2" nipple and 1/2" cross
into the stop/strainer check valve. Using the same thread sealer, thread the 1/2" elbow to the
other end of the stop/strainer check valve and then thread the elbow to the 1/2" stub-out from
the wall (see Figure 7b).
2. Install the drain plug in the hole in the bottom of the bowl (see Figure 8).
3. Beneath the bowl, install the 1/4" rubber washer onto the drain plug, and thread the tailpiece
to the drain plug.
4. Assemble the P-trap by connecting the 1-1/2" tubular pipe to the tailpiece and to the 1-1/2"
drain pipe stubbed out of the wall.
5. Install the strainer on the drain plug opening inside the bowl, and push the strainer firmly
into place. Secure the strainer to the drain with the screw provided.
Figure 7a
VERNATHERM™
THERMOSTATIC
MIXING VALVE
FIBER
WASHER
CONNECT TO
1/2" NPT COLD
WATER SUPPLY
CONNECT TO
1/2" NPT HOT
WATER SUPPLY
FLEXIBLE
SUPPLY
HOSE
1/2" CROSS
STOP/CHECK