Installation
S59-1005SR
Bradley
• 215-1674 Rev. F: ECO 19-03-024
1/8/2020
3
• Rough-in 1/2" NPT hot and cold water supply piping (supplied by installer) as shown below .
• For finished wall, make a 4-1/2" hole in the wall where the shower handle is desired .
HOT
COLD
SUPPLIES REVERSED
STANDARD INSTALL
Contact your Bradley
Representative and ask for
S45-2264 Back-to-Back Rotor
Kit to swap out the rotor on the
reversed side.
"Back-to-Back" Installation
6-1/2" (165)
w/Stops
2-1/2" (64)
w/o Stops
Hot
Cold
1-3/4"
(46)
(mm)
Rough-in
1
WARNING! In order for the shower to be ligature resistant, the valve inlet and outlet rough-ins
must be 4" (±1/8").
2-1/8"
(53)
1-1/2"
(38)
1-1/2"
(38)
48"
(1219)
Above
Finished
Floor
2-1/4"
(56)
4"*
(103)
4-5/8"*
(119)
Finished Wall
1/2" NPT Inlets
and Outlets
1/2" NPT
Pipe Plug
(By Installer)
Valve must
be 90° to wall
* Dimension can be ±1/8"