Position valve with port labeled “UP” towards showerhead . 
Connect valve to hot and cold supplies and showerhead 
or tub spout supplies (see rough-in diagram .)

B

Turn on hot and cold supplies to pressurize valve and check for 
leaks . (Valve will not operate unless both hot and cold supplies 
are turned on .) Adjust maximum temperature by turning set 
screw on valve cap .

C

H

E

Insert the 4 screws through the 
escutcheon and into the valve body . 
Tighten the screws, making sure that 
the escutcheon is flush with the wall or 
fixture and all 4 screws are tightened 
equally .

WARNING! The temperature limit stop has been 

factory preset for maximum temperature 

operation. Failure to adjust the limit screw 

to a safe shower temperature could result 

in the user being scalded.

Connect Valve and Adjust Valve Temperature

2

Attach Escutcheon and Handle

3

D

Apply 100% silicone caulk to all 
screw backsides prior to escutcheon 
installation .

A

Slide handle over stem . Apply semi-
permanent thread locker to set screw 
and tighten to ensure the screw is fully 
engaged .

B

Apply supplied silicone 
grease to o-ring to guide 
escutcheon in place .

C

Slide escutcheon on 
valve and align all 4 
holes .

F

Apply security sealant 
(if required) as 
described below .

After installation, all joints 
require security sealant (by 
installer) to eliminate gaps, 
if present, between the wall 
and fixture.

Содержание Equa-Flo S59-1005SR

Страница 1: ...ve and Adjust Valve Temperature 4 Attach Escutcheon and Handle 4 Read the instructions in this manual before beginning installation Save these instructions and refer to them for inspection maintenance and troubleshooting information For questions regarding the operation installation or maintenance of this product visit bradleycorp com or call 800 BRADLEY 800 272 3539 Product warranties and parts i...

Страница 2: ...water supply lines have been flushed and are then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction Installation of this system must be completed by a qualified plumber in compliance with all national and local codes Compliance and conformity to local codes and ordinances is the responsibility of the installer Should these codes differ from ...

Страница 3: ...ey Representative and ask for S45 2264 Back to Back Rotor Kit to swap out the rotor on the reversed side Back to Back Installation 6 1 2 165 w Stops 2 1 2 64 w o Stops Hot Cold 1 3 4 46 mm Rough in 1 WARNING In order for the shower to be ligature resistant the valve inlet and outlet rough ins must be 4 1 8 2 1 8 53 1 1 2 38 1 1 2 38 48 1219 Above Finished Floor 2 1 4 56 4 103 4 5 8 119 Finished Wa...

Страница 4: ...ws are tightened equally WARNING The temperature limit stop has been factory preset for maximum temperature operation Failure to adjust the limit screw to a safe shower temperature could result in the user being scalded Connect Valve and Adjust Valve Temperature 2 Attach Escutcheon and Handle 3 D Apply 100 silicone caulk to all screw backsides prior to escutcheon installation A Slide handle over s...

Отзывы: