MAINTENANCE

Form No. EBOOSTERBWM-1009

13

General

Bradford White Magnum Series Commercial Electric Booster

water heaters are designed for maximum durability and

performance, with minimum maintenance.

ELECTRIC SHOCK HAZARD:

• Turn power OFF at disconnect switch/circuit breaker

and allow unit to cool before performing any
maintenance or cleaning.

• This unit must be serviced by qualified personnel only.

Service by unqualified personnel may lead to electric
shock or burn.

• Use only Genuine Bradford White Replacement Parts

when service is required. Failure to use Genuine Bradford
White Replacement Parts will void all warranties and may
subject operators of the equipment to hazardous
electrical voltage, resulting in electrical shock or burn.
Genuine Bradford White Replacement Parts are specified
to operate safely in the environments in which they are
used. Some aftermarket or generic replacement parts do
not have the characteristics that will allow them to
operate safely in Bradford White equipment.

This unit has no “user-serviceable” parts. If service is
required on this unit, contact an Authorized Service Agent
or the Bradford White Service Department.

Thermostat Adjustment

The thermostat is factory calibrated to produce temperatures of

185°–190°F (85°–88°C). If adjustment or recalibration is

required use the following procedure.

NOTE: Low temperature dish machines require the thermostat

to be adjusted to 140°–150°F (60°–66°C).

1. Remove the access cover.

Figure 11. Access Cover for Thermostat and

High Temperature Limit Safety Switch

2. Adjust the thermostat in the desired direction.

• To

lower

the temperature setpoint, turn the outer

adjustment screw counterclockwise.

• To

raise

the temperature setpoint, turn the outer

adjustment screw clockwise.

Access Cover

High Temperature

Limit Safety Switch

Thermostat

WARNING

Figure 12. Thermostat Adjustment

NOTE: 1/6 turn of the outer screw equals 12°F (6.7°C).

If recalibration is necessary, with the outer screw at high stop

turn inner adjustment screw clockwise to raise the set point.

NOTE: 1/6 turn of the inner screw equals 8°F (4.4°C).

Temperature/Pressure Relief Valve

The temperature/pressure relief valve lever must be operated at

least once a year to ensure that waterways are clear. Certain

naturally occurring mineral deposits may adhere to the valve,

blocking waterways and rendering it inoperative. When the lever

is operated, hot water will discharge from the attached discharge

line if waterways are clear. In addition to annual operation of the

valve lever, the condition of the temperature/pressure relief valve

must be inspected every two to four years by a licensed plumber

or qualified service technician.

Inspect combination temperature/pressure relief valve at
least once every two to four years, depending on local
water conditions. Contact a licensed plumber or qualified
service technician for inspection. Replace valve, if
necessary. DO NOT attempt to self-inspect valve.

BURN HAZARD: Water in unit is very hot. Wear protective
gloves and proper attire when operating to avoid injury.

Use the following procedure to test the temperature/pressure

relief valve.

1. Make sure a properly installed

discharge line is connected to

the relief valve. The discharge

line must direct the flow of hot

water from the valve to a

proper place of disposal.

2. Pull up slightly on the relief valve

lever. The lever is connected to

a strong spring, so it will take

some force to move the lever.

• If water flows freely from the

discharge line, the valve is

clear and operating properly.

Release the lever down into the closed position (vertical).

• If water does not flow freely from the discharge line, the

valve is obstructed and must be replaced immediately.

Release the lever, turn off the booster water heater, and

contact a trained, licensed plumber to replace the valve.

NOTE: If dripping or discharge occurs when the relief valve

lever is in the closed position (vertical), turn off the

booster water heater and contact a licensed plumber

immediately. Discharge may indicate that an unsafe

temperature or pressure condition exists.

Temperature/Pressure

Relief Valve Lever

(Closed Position)

Discharge

Line

WARNING

Outer

Adjustment

Screw

Inner

Adjustment

Screw

Содержание LI6123CFC

Страница 1: ...sted no puede entender el contenido de este manual por favor pregunte a su supervisor Almacenar este manual en una localizaci n segura para la referencia futura Do not operate this equipment unless yo...

Страница 2: ...could result in death or serious injury CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to person...

Страница 3: ...N TEMPERATURE PRESSURE RELIEF VALVES IN ACCORDANCE WITH AMERICAN NATIONAL STD Z21 22 1979 Combination temperature pressure relief valves with extension thermostats must be installed so that the temper...

Страница 4: ...WARNING CAUTION Do not store any materials or items on or against the housing of the booster water heater Bradford White requires that two temperature pressure gauges be installed to assure proper ope...

Страница 5: ...ure gauges and a high temperature limit safety switch Magnum Series models feature a Castone tank with a 5 year limited warranty an ON OFF switch an indicator light and either 6 152 mm legs or slide m...

Страница 6: ...0 1 0 1 1 4 32 mm LI6243CFD 24 208 3 66 7 66 7 66 7 90 3 1 25 mm LI6243CFE 24 240 1 100 100 125 1 1 1 4 32 mm LI6243CFF 24 240 3 57 8 57 8 57 8 90 3 1 1 4 32 mm LI6243CFM 24 480 3 29 9 29 9 29 9 40 8...

Страница 7: ...0 kcmil 2 51 mm LI6453CFF 45 240 3 108 108 108 150 1 0 1 1 4 32 mm LI6453CFM 45 480 3 54 54 54 70 4 1 25 mm LI6543CFD 54 208 3 150 150 150 200 3 0 2 51 mm LI6543CFF 54 240 3 130 130 130 175 2 0 1 1 2...

Страница 8: ...nder dish table DO NOT mount on walls or in ceiling Unit must be accessible for service Improper installation could create an unsafe condition Booster Heaters are shipped with most components pre asse...

Страница 9: ...uges are supplied with all booster water heaters One temperature pressure relief valve supplied with all booster heaters Pressure Reducing Valve Shock Absorber Blended Phosphate Water Treatment System...

Страница 10: ...terways are clear This device is designated for emergency safety relief and shall not be used as an operating control The valves are set to relieve at 150 psi 1034 kPa or when water temperature reache...

Страница 11: ...nd reduce the operating life of the unit through increased lime build up Product failure caused by liming or sediment buildup is not covered under warranty Do not use deionized or reverse osmosis R O...

Страница 12: ...er Drain Valve 3 4 Union Floor Drain Outlet Inlet Discharge from T P relief valve Air gap must comply with plumbing code Blended Phosphate Water Treatment System Optional accessory Not supplied with b...

Страница 13: ...O A MINIMUM OF 40 INCH POUNDS NOTE Due to the rigors of transportation all connections should be checked for tightness before booster water heater is put into operation 4 A grounding lug is provided n...

Страница 14: ...unit will get hot Avoid unnecessary contact with unit 6 Turn on the electrical supply to the booster heater 7 Move the Power ON OFF switch to the ON position The indicator light will turn on Figure 1...

Страница 15: ...clockwise to raise the set point NOTE 1 6 turn of the inner screw equals 8 F 4 4 C Temperature Pressure Relief Valve The temperature pressure relief valve lever must be operated at least once a year t...

Страница 16: ...alled properly 8 A check valve should not be installed ahead of the booster NOTE If a check valve is installed and cannot be removed install a back pressure relief valve set at 125 psi 862 kPa on the...

Страница 17: ...be reset contact an Authorized Service Agent Low water cutoff inoperable contacts do not close Contact Authorized Service Agent or Bradford White for assistance Transformer not working properly Contac...

Страница 18: ...ew valve with built in bypass Check valve or anti siphon valve installed in the feed line Remove check valve or anti siphon valve to allow for water expansion or install a back pressure relief valve o...

Страница 19: ...e floor Shock Absorber The shock absorber installed between the booster and the commercial dish machine reduces water hammer induced by rapidly operating valves The water hammer can cause damage to th...

Страница 20: ...WIRING DIAGRAMS Form No EBOOSTERBWM 1009 18 10 01 454 6 9 kW Wiring Diagram All Voltages Single or Three Phase 10 01 448 12 18 kW Wiring Diagram All Voltages Three Phase...

Страница 21: ...WIRING DIAGRAMS Form No EBOOSTERBWM 1009 19 10 01 452 12 15 kW Wiring Diagram 208 and 240 V Single Phase 10 01 447 18 kW Wiring Diagram 208 and 240 V Single Phase...

Страница 22: ...WIRING DIAGRAMS Form No EBOOSTERBWM 1009 20 10 01 432 24 30 kW Wiring Diagram 240 V Single Phase 10 01 433 24 36 kW Wiring Diagram 208 and 240 V Three Phase...

Страница 23: ...WIRING DIAGRAMS Form No EBOOSTERBWM 1009 21 10 01 435 24 36 kW Wiring Diagram 480 V Three Phase 10 01 436 36 kW Wiring Diagram 240 V Single Phase...

Страница 24: ...WIRING DIAGRAMS Form No EBOOSTERBWM 1009 22 10 01 434 45 57 kW Wiring Diagram 480 V Three Phase 10 01 437 36 57 kW Wiring Diagram 208 and 240 V Three Phase...

Страница 25: ...ank only WHAT IS THE DURATION OF THE IMPLIED WARRANTY ANY IMPLIED WARRANTIES INCLUDING THE WARRANTY OF MERCHANTABILITY IMPOSED ON THE SALE OF THE WATER HEATER UNDER THE LAWS OF THE STATE OF SALE ARE L...

Страница 26: ...ecessary allow us or our chosen representative to inspect the unit 5 For your reference fill in the Model and Serial Number found on the units Rating Plate Model Number _______________________________...

Страница 27: ...NOTES Form No EBOOSTERBWM 1009 25...

Страница 28: ...rinted in U S A October 2009 Part No 07 04 474 00 Form No EBOOSTERBWM 1009 Ambler PA 19002 Technical Service 800 334 3393 Service Parts 800 538 2020 Warranty Service 800 531 2111 www bradfordwhite com...

Отзывы: