background image

Other possible solutions: 

 

NOTE:  BE SURE ELECTRICITY IS TURNED OFF BEFORE PROCEEDING

 

 

STEP ONE: 
 
Make sure the printed circuit board is mounted in the correct position. This is the top 
set of mounting holes (See diagram below). Failure to mount PCB in the correct  
position will cause element burn out and may cause further damage to the unit 
(This board may have been incorrectly positioned if serviced previously).

 

 

 
 
 
 
 
 
 
 
 
 
 

 
 

 

 
 
 
 
 
 
 

 
 
 

 
 
 

 

The correct mounting holes
for the PCB on an “ES,EFC,
EFT” model.

Board mounted in correct

position

 

Inlet filter

 

STEP TWO: 
 
Inspect the inlet filter (See diagram above for location). Make sure the inlet filter 
screen is free from debris, pipe dope or any other foreign materials that may prevent 
adequate water flow. 
 

6

 

 

Содержание EFT-5500-4-S-10

Страница 1: ...EFT 9000 4 S 10 277V EFT 10000 4 S 10 277V THERMOSTATIC EFT MODELS All information necessary to troubleshoot this water heating unit is contained in this fully illustrated guide If problems still exi...

Страница 2: ...dicator light illuminates when the hot water faucet is fully opened If the indicator light illuminates turn to page 5 If the indicator light does not illuminate turn to page 3 If the indicator light f...

Страница 3: ...ific model flow rates Measure the flow rate using the following procedure Fill a 1 gallon milk container and using only water from the hot water faucet record the time In seconds required to fill To c...

Страница 4: ...ods with brass nuts on them Where the wires connect Take a reading of the ohms value between these two rods and write it down See diagram below If the reading is less then 20 ohms on the single Rx1 sc...

Страница 5: ...O Make sure the unit is connected to the voltage supply specified on the U L rating label located on the front cover of the unit STEP THREE Proceed to page four and follow STEP THREE Indicator light i...

Страница 6: ...osition will cause element burn out and may cause further damage to the unit This board may have been incorrectly positioned if serviced previously The correct mounting holes for the PCB on an ES EFC...

Страница 7: ...aucet for 30 seconds and then switch power ON to the unit with the water flowing 0 75 GPM If the light illuminates steadily then call Technical Service and request a replacement printed circuit board...