GENERAL 

 
 

2

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
This is how your EFT thermostatic model should look when mounted correctly on 
the wall. 

  

 
Any other mounting configuration will prevent the unit from operating properly. 
  
If the unit is mounted correctly and still does not produce hot water, then look to 
see if the indicator light illuminates when the hot water faucet is fully opened. 

  

 
If the indicator light illuminates, turn to page 5. 
If the indicator light does not illuminate, turn to page 3. 
If the indicator light flashes once very quickly as you turn the water “ON”, turn to 
page 7. 
 
If the indicator light is pulsing, refer to the bottom of page 5.  
All other possible situations turn to page 6.  

U.L. rating label    
Model # = Order Ref. # 

UP 

   

Serial number 

Indicator 
light 

  
 

  
 

Water outlet/inlet (Bottom) 

 Out     In

Содержание EFT-5500-4-S-10

Страница 1: ...EFT 9000 4 S 10 277V EFT 10000 4 S 10 277V THERMOSTATIC EFT MODELS All information necessary to troubleshoot this water heating unit is contained in this fully illustrated guide If problems still exi...

Страница 2: ...dicator light illuminates when the hot water faucet is fully opened If the indicator light illuminates turn to page 5 If the indicator light does not illuminate turn to page 3 If the indicator light f...

Страница 3: ...ific model flow rates Measure the flow rate using the following procedure Fill a 1 gallon milk container and using only water from the hot water faucet record the time In seconds required to fill To c...

Страница 4: ...ods with brass nuts on them Where the wires connect Take a reading of the ohms value between these two rods and write it down See diagram below If the reading is less then 20 ohms on the single Rx1 sc...

Страница 5: ...O Make sure the unit is connected to the voltage supply specified on the U L rating label located on the front cover of the unit STEP THREE Proceed to page four and follow STEP THREE Indicator light i...

Страница 6: ...osition will cause element burn out and may cause further damage to the unit This board may have been incorrectly positioned if serviced previously The correct mounting holes for the PCB on an ES EFC...

Страница 7: ...aucet for 30 seconds and then switch power ON to the unit with the water flowing 0 75 GPM If the light illuminates steadily then call Technical Service and request a replacement printed circuit board...

Отзывы: