                                     WARNING! 
          TURN OFF THE CIRCUIT BREAKER BEFORE 
                PROCEEDING WITH THE NEXT TESTS. 

CHECKING THERMOSTATIC CIRCUIT BOARD

 

 

If the LED on the circuit board flashes one time very quickly when the water is switched ON then:

 

 

1) Turn 

“OFF”

 the power to this unit and all other units that may feed hot water to this unit. 

 
2) Be sure that this unit is fed with cold water only. This unit must not be fed with pre-heated water 
when performing this test. 
 
3) There are six thin leads connected to the printed circuit board. Disconnect the third wire from 
the left, from the top of the PCB (As indicated below) and tape off the end with insulating tape. 
 
4) Run water from hot water faucet for 30 seconds and then switch power 

“ON”

 to the unit, 

with 

the water flowing @ 0.75 GPM.  

If the light illuminates steadily then call Technical Service and 

request a replacement printed circuit board

 

(Part # EX 100). If the light still does not illuminate, 

contact Technical Service and consult with a technician.

  

3rd wire from left

3rd wire from left

 
 
 
 

7

 

 

 
 
 

WARNING

 

Do not use this unit with any pre-heated water feed if the light 

has illuminated steadily having performed the above test. 

The unit in this state must only

 
 
 

IF HAVING CARRIED OUT ALL THE TESTS LISTED ABOVE AND THE WATER  

HEATING UNIT IS STILL NOT FUNCTIONING, PLEASE CALL TECHNICAL 

SERVICE AT 1-800-334-3393.

     

              

PLEASE HAVE THE FOLLOWING INFORMATION AVAILABLE: 
1)  ORDER REF. NUMBER (Located on U.L. rating label on the front cover of unit). 

2)

  SERIAL NUMBER (Inside unit on back plate).

 

 be fed with cold water.

 

Содержание EFT-5500-4-S-10

Страница 1: ...EFT 9000 4 S 10 277V EFT 10000 4 S 10 277V THERMOSTATIC EFT MODELS All information necessary to troubleshoot this water heating unit is contained in this fully illustrated guide If problems still exi...

Страница 2: ...dicator light illuminates when the hot water faucet is fully opened If the indicator light illuminates turn to page 5 If the indicator light does not illuminate turn to page 3 If the indicator light f...

Страница 3: ...ific model flow rates Measure the flow rate using the following procedure Fill a 1 gallon milk container and using only water from the hot water faucet record the time In seconds required to fill To c...

Страница 4: ...ods with brass nuts on them Where the wires connect Take a reading of the ohms value between these two rods and write it down See diagram below If the reading is less then 20 ohms on the single Rx1 sc...

Страница 5: ...O Make sure the unit is connected to the voltage supply specified on the U L rating label located on the front cover of the unit STEP THREE Proceed to page four and follow STEP THREE Indicator light i...

Страница 6: ...osition will cause element burn out and may cause further damage to the unit This board may have been incorrectly positioned if serviced previously The correct mounting holes for the PCB on an ES EFC...

Страница 7: ...aucet for 30 seconds and then switch power ON to the unit with the water flowing 0 75 GPM If the light illuminates steadily then call Technical Service and request a replacement printed circuit board...

Отзывы: