The indicator light illuminates but water is not heated or the 

water temperature is too low: 

 

STEP ONE: 
 
The water flow is too high. Reduce the water flow using the faucet. With 
experimentation, an increase in water temperature should be observed. 
BE CAREFUL, THE WATER EXITING THE FAUCET IS HOT. SCALD 
INJURY CAN OCCUR FROM THE HOT WATER. 
 
STEP TWO: 
 
Make sure the unit is connected to the voltage supply specified on the 
U.L. rating label located on the front cover of the unit. 
 
STEP THREE: 
 
Proceed to page four and follow STEP THREE. 
 

Indicator light is pulsing and the water temperature is too low

 

 

 

Turn the temperature adjustment screw on the printed circuit board 
clockwise. Turn the screw very gently; the maximum position is 
approximately 5 o’clock. At this point the light should stop flashing 
and should be illuminated continuously when water is flowing.

 

 
 
 
 
 
 
 

 
 
 
 
 

 

Temperature adjustment

screw

 

 

5

 

 

Содержание EFT-5500-4-S-10

Страница 1: ...EFT 9000 4 S 10 277V EFT 10000 4 S 10 277V THERMOSTATIC EFT MODELS All information necessary to troubleshoot this water heating unit is contained in this fully illustrated guide If problems still exi...

Страница 2: ...dicator light illuminates when the hot water faucet is fully opened If the indicator light illuminates turn to page 5 If the indicator light does not illuminate turn to page 3 If the indicator light f...

Страница 3: ...ific model flow rates Measure the flow rate using the following procedure Fill a 1 gallon milk container and using only water from the hot water faucet record the time In seconds required to fill To c...

Страница 4: ...ods with brass nuts on them Where the wires connect Take a reading of the ohms value between these two rods and write it down See diagram below If the reading is less then 20 ohms on the single Rx1 sc...

Страница 5: ...O Make sure the unit is connected to the voltage supply specified on the U L rating label located on the front cover of the unit STEP THREE Proceed to page four and follow STEP THREE Indicator light i...

Страница 6: ...osition will cause element burn out and may cause further damage to the unit This board may have been incorrectly positioned if serviced previously The correct mounting holes for the PCB on an ES EFC...

Страница 7: ...aucet for 30 seconds and then switch power ON to the unit with the water flowing 0 75 GPM If the light illuminates steadily then call Technical Service and request a replacement printed circuit board...

Отзывы: