The indicator light does not illuminate (When the hot water faucet is 

fully opened): 

 
 

STEP ONE: 
 
Is the circuit breaker switched on at the main circuit breaker panel? 
       YES                   Go to Step two 
    
       NO  

                                     Run water at the hot water faucet, for a couple of 

 

 

                                                          minutes, before turning on the circuit breaker.  

Then turn on the circuit breaker at the main 
circuit breaker panel.   

 

STEP TWO: 
 
The heating elements will not energize unless sufficient water is flowing through the 
unit. 

The minimum acceptable flow rate is 0.55 gallons per minute.  Some 
models require a higher flow rate, see chart below for specific

 

model flow 

rates.  Measure the flow rate using the following procedure: 

 
 

Fill a 1-gallon “milk” container and, using only water from the hot water  

 

faucet, record the time (In seconds) required to fill. To calculate the flow  
rate, divide the number of gallons the container holds (In this case one 
gallon) by the time required to fill. 
 
e.g. If it takes 87 seconds to fill the container, then the flow rate would be: 

 

Flow rate (gpm) = v/t x 60 = (1 gal./ 87 sec) x (60 sec./1 min.) = 0.69 gpm.  

 

 
Open all water valves completely. If the indicator light still does not 
illuminate then proceed to STEP THREE.

 

 
 
 
 
 
 
 
 
 

 

MODEL TYPE / ORDER REF#                    MINIMUM FLOW RATE 
                                            
EFT-5500-4-S-10, EFT-6000-4-S-10                         0.55  GPM 
EFT-7500-4-S-10, EFT-8000-4-S-10, 
EFT-8300-4-S-10                                                        0.65  GPM 
EFT-9000-4-S-10, EFT-9500-4-S-10, 
EFT-10000-4-S-10                                                      0.75  GPM

3

 

 

Содержание EFT-5500-4-S-10

Страница 1: ...EFT 9000 4 S 10 277V EFT 10000 4 S 10 277V THERMOSTATIC EFT MODELS All information necessary to troubleshoot this water heating unit is contained in this fully illustrated guide If problems still exi...

Страница 2: ...dicator light illuminates when the hot water faucet is fully opened If the indicator light illuminates turn to page 5 If the indicator light does not illuminate turn to page 3 If the indicator light f...

Страница 3: ...ific model flow rates Measure the flow rate using the following procedure Fill a 1 gallon milk container and using only water from the hot water faucet record the time In seconds required to fill To c...

Страница 4: ...ods with brass nuts on them Where the wires connect Take a reading of the ohms value between these two rods and write it down See diagram below If the reading is less then 20 ohms on the single Rx1 sc...

Страница 5: ...O Make sure the unit is connected to the voltage supply specified on the U L rating label located on the front cover of the unit STEP THREE Proceed to page four and follow STEP THREE Indicator light i...

Страница 6: ...osition will cause element burn out and may cause further damage to the unit This board may have been incorrectly positioned if serviced previously The correct mounting holes for the PCB on an ES EFC...

Страница 7: ...aucet for 30 seconds and then switch power ON to the unit with the water flowing 0 75 GPM If the light illuminates steadily then call Technical Service and request a replacement printed circuit board...

Отзывы: