1) This unit is supplied with compression fittings, USE THESE; DO NOT USE TAPERED
THREADED PIPE FITTINGS AND DO NOT SOLDER PIPE TO THE INLET OR OUTLET.
2) Ensure that the pipes are correctly aligned with the inlet and outlet bosses in
order to avoid excessive stress on the heater body molding of the unit.
NOTE: When soldering pipe joints remove unit from the wall. Serious damage can occur
if any soldering is done while pipes are connected to the unit.
Run water through the supply pipe to remove all debris from the pipe before connecting to
the unit. Failure to do so could cause damage to the flow switch.
3) Install isolating valves (full flow ball valve type) on both inlet and outlet pipes. This allows
the unit to be isolated for maintenance purposes.
4) When all plumbing is complete, inspect the system for water leaks at all plumbing
connections. If a water leak is present take corrective action. If a water leak is at a
compression fitting, slowly tighten the compression nut until the water leak stops. Fully open
both inlet and outlet ball valves. Run all hot water outlets fed by this water heating unit one
at a time until the water flow is continuous and free from ”gulping” and all visible air
pockets.
PLUMBING HOOK-UP
NOTE
ALL MOUNTING AND PLUMBING MUST BE COMPLETE BEFORE PROCEEDING
WITH ELECTRICAL HOOK-UP.
TEST THE INSTALLATION FOR LEAKS BEFORE CONNECTING THE
ELECTRICAL SUPPLY.
7 “
Hot water outlet
compression
fitting
DO NOT
SOLDER
Cold water inlet
compression
fitting
DO NOT
SOLDER
4