SYMPTOM

POSSIBLE CAUSE

SOLUTION

NO HEAT -
INDICATOR LIGHT 
OFF

A) ELECTICAL SUPPLY OFF

B) NO OR LOW WATER 
FLOW

C) WATER CONNECTION 
REVERSED

D) ELEMENT BURNED OUT

TURN ON MAIN MAIN CIRCUIT BREAKER

MINIMUM WATER FLOW TO TURN ON UNIT IS 0.7 
GALLON PER MINUTE. INCREASE FLOW TO AT 
LEAST THIS LEVEL.

COLD WATER INLET-RIGHT SIDE. HOT WATER 
OUTLET - LEFT SIDE. REFER TO FIG. 1

1) 

TURN MAIN BREAKER OFF

2) USING OHMETER TEST RESISTENCE OF THE 

HEATING ELEMENT AT TWO TERMINATION 

RODS ON THE TOP OF ELEMENT.  SEE FIGURE

BELOW.

3) OHMETER SHOULD READAS FOLLOWS:

- 6-7 OHMS

- 7-8 OHMS

- 10-11 OHMS

IF RESISTENCE OF THE ELEMENT IS MUCH 
GREATER THAN THESE READINGS - CALL 
TECHNICAL SUPPORT.

NO HAET OR LOW 

TEMERATURE 

INDICATOR LIGHT ON

A)  WATER FLOW TOO 
HIGH

REDUCE WATER FLOW BY USING OUTLET BALL 
VALVE. SEE ”RATINGS OF UNITS” TABLE P- FOR 
TEMPERATURE RISE @ 1 GPM.

B) 110 VOLT POWER 
SUPPLY INSTEAD OF 240 
VOLTS

UNIT MUST BE CONNECTED TO 240 VOLT 
POWER POWER SUPPLY.  SEE SECTION III -
ELECTRICAL HOOK-UP.

C) ELEMENT BURNED OUT

1) 

TURN MAIN BREAKER OFF

2) USING OHMETER TEST RESISTENCE OF 
THE 

HEATING ELEMENT AT TWO TERMINATION 

RODS ON THE TOP OF ELEMENT.  SEE 

FIGURE

BELOW.

3) OHMETER SHOULD READAS FOLLOWS:

- 6-7 OHMS

- 7-8 OHMS

- 10-11 OHMS

IF RESISTENCE OF THE ELEMENT IS MUCH 
GREATER THAN THESE READINGS - CALL 
TECHNICAL SUPPORT.

Содержание EFT-18000-2-T-10

Страница 1: ...R INSTALLATION AND OPERATION THE WARRANTY SHALL BE VOID IF THE DESIGN HAS BEEN ALTERED IN ANY WAY WHATSOEVER THE MANUFACTURER OF THIS UNIT WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMP...

Страница 2: ...bly rated three pole breaker The maximum voltage which can be applied across any heating module is 277 volts It is recommended that a Pressure Relief Valve be installed as close as possible to the hea...

Страница 3: ...ing system in such a way that there is no tendency for the unit to be starved of water for example by an excessive draw off of cold water just before the unit Also do not fit an unrestricted hot water...

Страница 4: ...l valve type on both inlet and outlet pipes This allows the unit to be isolated for maintenance purposes 4 When all plumbing is complete inspect the system for water leaks at all plumbing connections...

Страница 5: ...OCKETS OR PREMATURE FAILURE OF THE ELEMENT WILL OCCUR TO DO THIS OPEN ALL HOT WATER OUTLETS ONE AT A TIME FOR A MINUTE OR TWO UNTIL THE WATER FLOW IS CONTINUOUS AND FREE FROM GULPING AND FROM VISIBLE...

Страница 6: ...s point water temperature may not be hot 5 Using the OUTLET BALL VALVE slowly reduce water flow until desired water temperature is achieved at hot water outlet NOTE The water temperature is regulated...

Страница 7: ...at the set temperature Check that the temperature is what is required The thermostat is now set and the water temperature will remain constant when the indicator light is pulsing 6 Check the performa...

Страница 8: ...6 7 OHMS 7 8 OHMS 10 11 OHMS IF RESISTENCE OF THE ELEMENT IS MUCH GREATER THAN THESE READINGS CALL TECHNICAL SUPPORT NO HAET OR LOW TEMERATURE INDICATOR LIGHT ON A WATER FLOW TOO HIGH REDUCE WATER FLO...

Страница 9: ......

Страница 10: ...connection with a maximum of 277 volts across each element REPLACEMENT PARTS DIAGRAM THERMOSTATIC PCB PART EX100 VOLTAGE HEATER CORE ASSEMBLY FOR TRIAC PART EX18 8 EFT 18000 T 10 277V EX1280 EFT 1800...

Отзывы: