background image

OPERATING THE WATER HEATER

WARNING

HOUSEHOLDS WITH SAMLL CHILDREN OR ELDERLY PERSONS MAY 

REQUIRE WATER TEMPERATURES OF  125°F(52°C) OR LOWER TO 

PREVENT ACCIDENTAL SCALDING FROM CONTACT WITH THE 

WATER

1) Completely open both the inlet and outlet valves at the unit.

2) Open all hot water outlets serviced by this unit.  If the outlet is a mixer type adjust to the hottest position.   
Run flow until flow is continuous at all the outlets.  When the flow is continuous at all serviced outlets, 
proceed to the next step.

3) Switch on electric supply at the circuit breaker panel.  The indicator light on the unit should now 
illuminate.

4) Using the outlet BALL VALVE, slowly reduce the water flow until the desired water temperature is 
achieved at the hot water outlet.  This should be 120°f(49°c) to 140°f(60°c) without mixing with cold water.  

5) Turn the temperature adjustment screw counter clockwise about 1/8 of a turn.  After 10-15 seconds,  the 
power indicator light should be pulsing.  If it does not, turn the screw counter-clockwise another 1/8 of a turn.  
Wait 10-15 seconds for the indicator light to begin pulsing.  Repeat process until the indicator light is pulsing 
regularly.  This indicates that the water temperature has stabilized at the set temperature.  Check that the 
temperature is what is required.  The thermostat is now set and the water temperature will remain constant 
when the indicator light is pulsing.

6) Check the performance of the flow switch by opening and closing the faucet a few times.

THE POWER INDICATOR LIGHT SHOULD ONLY ILLUMINATE WHEN WATER IS FLOWING 
TROUGH THE UNIT.

NOTE: An EFT-9500-S-10 (9.5 kw) unit at 240v will deliver 1 gallon per minute at 65°F(18°C) rise in 
temperature.  For example, with an incoming water temperature of 55°F(13°C) the unit will produce 1 gallon 
per minute at 120°F(49°C)

A flow rate of 1 gallon per minute will fill a 1 gallon “milk” container in 60 seconds.

7) For accurate water temperature control a mixer type faucet(single spout), the cold water supply to the 
faucet should be restricted to give approximately the same flow rate of cold water to the faucet as the hot 
water exiting the unit.  The simplest method of achieving this is by partially closing the cold water valve 
under the sink.

8) It is possible that drawing off cold water at comparatively high rates of flow elsewhere in the building at 
the same time that the unit is working, could starve the unit of cold water.  Care should be taken to avoid this 
from occuring as premature element failure may result.  Completely open the main valve on the cold supply 
to the building and throttle back the control valvues to the other cold water outlets.    

Содержание EFT-18000-2-T-10

Страница 1: ...R INSTALLATION AND OPERATION THE WARRANTY SHALL BE VOID IF THE DESIGN HAS BEEN ALTERED IN ANY WAY WHATSOEVER THE MANUFACTURER OF THIS UNIT WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMP...

Страница 2: ...bly rated three pole breaker The maximum voltage which can be applied across any heating module is 277 volts It is recommended that a Pressure Relief Valve be installed as close as possible to the hea...

Страница 3: ...ing system in such a way that there is no tendency for the unit to be starved of water for example by an excessive draw off of cold water just before the unit Also do not fit an unrestricted hot water...

Страница 4: ...l valve type on both inlet and outlet pipes This allows the unit to be isolated for maintenance purposes 4 When all plumbing is complete inspect the system for water leaks at all plumbing connections...

Страница 5: ...OCKETS OR PREMATURE FAILURE OF THE ELEMENT WILL OCCUR TO DO THIS OPEN ALL HOT WATER OUTLETS ONE AT A TIME FOR A MINUTE OR TWO UNTIL THE WATER FLOW IS CONTINUOUS AND FREE FROM GULPING AND FROM VISIBLE...

Страница 6: ...s point water temperature may not be hot 5 Using the OUTLET BALL VALVE slowly reduce water flow until desired water temperature is achieved at hot water outlet NOTE The water temperature is regulated...

Страница 7: ...at the set temperature Check that the temperature is what is required The thermostat is now set and the water temperature will remain constant when the indicator light is pulsing 6 Check the performa...

Страница 8: ...6 7 OHMS 7 8 OHMS 10 11 OHMS IF RESISTENCE OF THE ELEMENT IS MUCH GREATER THAN THESE READINGS CALL TECHNICAL SUPPORT NO HAET OR LOW TEMERATURE INDICATOR LIGHT ON A WATER FLOW TOO HIGH REDUCE WATER FLO...

Страница 9: ......

Страница 10: ...connection with a maximum of 277 volts across each element REPLACEMENT PARTS DIAGRAM THERMOSTATIC PCB PART EX100 VOLTAGE HEATER CORE ASSEMBLY FOR TRIAC PART EX18 8 EFT 18000 T 10 277V EX1280 EFT 1800...