All piping components connected to this water heater for space heating applications 
must be suitable for use with potable water.  In Massachusetts, space heating piping 
length 

must not

 exceed 50 feet. 

1.  Toxic chemicals, such as those used for boiler treatment, 

must not 

be introduced 

into potable water used for space heating. 

2.  This water heater 

must not

 be connected to an existing heating system or 

component(s) previously used with a non-potable water   heating appliance. 

3.  When the system requires water for space heating at temperatures higher than 

required for other means, such as an ASSE approved mixing valve must be 
installed to temper the water for those uses in order to reduce the scald hazard 
potential. 

 
Please refer to Figure 6 for suggested piping arrangements. 

 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 6

 

 

Содержание Defender Safety System 238-48248-00

Страница 1: ...on Resistant System In the event of improper usage or storage of gasoline or other flammable materials in the location where the water heater is installed the technology will resist ignition of the fl...

Страница 2: ...must be installed on top of a metal or wood panel or equivalent extending beyond the full width and depth of the water heater by at least 3 in 7 6 cm in any direction or if the appliance is to be ins...

Страница 3: ...ance if any part has been under water Immediately call a qualified technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water a fi...

Страница 4: ...lockwise to decrease the temperature setting Rotate the thermostat dial clockwise to increase the temperature setting Adjust the dial until the minimum acceptable temperature is achieved DANGER Hotter...

Страница 5: ...adjusting air mixture and do not have an adjustable air shutter See Figure 3 At periodic intervals a visual check of the main burner and pilot flames should be made to determine if they are burning p...

Страница 6: ...6 INSTALLATION FOR POTABLE WATER Replaces pg 28 in instruction manual Figure 4...

Страница 7: ...7 PARTS LIST DRAWING Replaces pg 29 in instruction manual Figure 5 1 3 4 5 6 7 8 9 10 12 13 14 15 16 15A 19 20 21 22 23 24 25 27 28 11 26 2 18 17...

Страница 8: ...ccessory Module 4 Jacket 18 Junction box wire harness 5 Heat trap outlet 19 Thermal well 6 Anode Outlet Device 20 Gas control 7 Heat trap inlet 21 FV sensor RTS wire harness 8 Baffle 22 FV sensor clip...

Страница 9: ...emicals such as those used for boiler treatment must not be introduced into potable water used for space heating 2 This water heater must not be connected to an existing heating system or component s...

Страница 10: ...ed with a flammable vapor water heater control will shut down the water heater and display a code of 7 flashes and then a 3 second pause If a 7 flash error code is present check to see if flammable va...

Страница 11: ...d Accessory Module If wiring in conduit is required cut the flexible line cord at least 6 in 15 2 cm from the bushing Unscrew and remove the Setback Control Junction Box Assembly lid Pull the cord int...

Страница 12: ...REPLACED WITH APPLIANCE WIRE MATERIAL WITH A MINIMUM TEMPERATURE RATING OF 105 C AND A MINIMUM SIZE OF NO 18 AWG ELECTRICAL RATING HOT LOW HOT VERY A C B Honeywell W PILO SETBACK GAS R B W B G Y POWER...

Страница 13: ...t 2 Pilot tube block or restricted 3 Oxidation build up on pilot electrode 4 Wire damage to pilot assembly or bad connection at gas valve Two flashes three second pause Relay not working Faulty relay...

Страница 14: ...r exposed to excessive moisture 3 Flammable vapor sensor exposed to extreme ambient temperature 4 Resettable thermal switch open Eight flashes one flash three second pause Flammable vapor sensor out o...

Страница 15: ...sends power to the relay which then closes the relay contacts 4 The control starts the ignition process by providing a spark at the pilot electrode and allowing gas to flow to the pilot 5 When the pil...