background image

14 

Troubleshooting continued-

 

 

LED Status

Control Status

Probable Cause

Six  f lashes,  t w o 

f lashes, three 

second pause 

(Sof t   Lockout )

Relay not  w orking properly 

during burner operat ion, 

syst em aut o reset s aft er 

(5) minut es

Fault y relay

Six  f lashes,  t hree 

f lashes, three 
second pause 

(Sof t  Lockout )

Pilot  f lame ext inguished, 

syst em aut o reset s aft er 

(5) minut es

1. Unst able pilot
2. Pilot  t ube block or restrict ed
3. Oxidat ion build-up on pilot  elect rode
4. Wire damage to pilot  assembly or bad 
connect ion at  gas valve
5. Insuf f icient   combust ion  air

Six f lashes, f our 

f lashes, three 
second pause

Undesired f alse pilot  f lame 

sensed, syst em auto 

resets

Pilot  valve st uck in open posit ion

Seven f lashes, 

three second 

pause

Flammable vapor sensor or 

reset t able  t hermal  sw it ch 

f ault   det ect ed,  see 

w arning label

1. Flammable vapor present
2. Flammable vapor sensor exposed t o 
excessive moist ure
3. Flammable vapor sensor exposed t o 
ext reme ambient  t emperat ure
4. Reset t able  t hermal  sw it ch  open

Eight  f lashes, one 

flash, t hree 

second pause

Flammable vapor sensor 

out  of  specif icat ion, 

possible short

1. Flammable vapor sensor out  of  
specif icat ion
2. Possible short  in f lammable vapor sensor 
or reset t able  t hermal  sw itch  w iring

Eight  f lashes, 

t hree  f lashes, 

three second 

pause

Thermal w ell sensor 

damaged or unplugged or 

gas valve electronics fault  

det ected

1. Damage t o t hermal w ell w ires
2. Thermal w ell sensor resist ance out  of 
range
3. Replace t hermal w ell
4. Verif y cont rol is not  w et  or physically 
damaged
5. Reset   cont rol  on/of f   sw it ch
6. Replace elect ronic module if  8-3 error 
persist s

Eight  f lashes, f our 

f lashes, three 

second pause

Gas  valve  f ault   det ect ed

1. Verif y cont rol is not  w et  or physically 
damaged
2. Reset   cont rol  on/of f   sw it ch
3. Replace gas cont rol if  8-4 error persist s

 

 

Fault Probable 

Cause 

Resettable Thermal Switch Tripped (Open) 

1.  Insufficient combustion air 
2.  Flammable vapors present 

 

Содержание Defender Safety System 238-48248-00

Страница 1: ...on Resistant System In the event of improper usage or storage of gasoline or other flammable materials in the location where the water heater is installed the technology will resist ignition of the fl...

Страница 2: ...must be installed on top of a metal or wood panel or equivalent extending beyond the full width and depth of the water heater by at least 3 in 7 6 cm in any direction or if the appliance is to be ins...

Страница 3: ...ance if any part has been under water Immediately call a qualified technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water a fi...

Страница 4: ...lockwise to decrease the temperature setting Rotate the thermostat dial clockwise to increase the temperature setting Adjust the dial until the minimum acceptable temperature is achieved DANGER Hotter...

Страница 5: ...adjusting air mixture and do not have an adjustable air shutter See Figure 3 At periodic intervals a visual check of the main burner and pilot flames should be made to determine if they are burning p...

Страница 6: ...6 INSTALLATION FOR POTABLE WATER Replaces pg 28 in instruction manual Figure 4...

Страница 7: ...7 PARTS LIST DRAWING Replaces pg 29 in instruction manual Figure 5 1 3 4 5 6 7 8 9 10 12 13 14 15 16 15A 19 20 21 22 23 24 25 27 28 11 26 2 18 17...

Страница 8: ...ccessory Module 4 Jacket 18 Junction box wire harness 5 Heat trap outlet 19 Thermal well 6 Anode Outlet Device 20 Gas control 7 Heat trap inlet 21 FV sensor RTS wire harness 8 Baffle 22 FV sensor clip...

Страница 9: ...emicals such as those used for boiler treatment must not be introduced into potable water used for space heating 2 This water heater must not be connected to an existing heating system or component s...

Страница 10: ...ed with a flammable vapor water heater control will shut down the water heater and display a code of 7 flashes and then a 3 second pause If a 7 flash error code is present check to see if flammable va...

Страница 11: ...d Accessory Module If wiring in conduit is required cut the flexible line cord at least 6 in 15 2 cm from the bushing Unscrew and remove the Setback Control Junction Box Assembly lid Pull the cord int...

Страница 12: ...REPLACED WITH APPLIANCE WIRE MATERIAL WITH A MINIMUM TEMPERATURE RATING OF 105 C AND A MINIMUM SIZE OF NO 18 AWG ELECTRICAL RATING HOT LOW HOT VERY A C B Honeywell W PILO SETBACK GAS R B W B G Y POWER...

Страница 13: ...t 2 Pilot tube block or restricted 3 Oxidation build up on pilot electrode 4 Wire damage to pilot assembly or bad connection at gas valve Two flashes three second pause Relay not working Faulty relay...

Страница 14: ...r exposed to excessive moisture 3 Flammable vapor sensor exposed to extreme ambient temperature 4 Resettable thermal switch open Eight flashes one flash three second pause Flammable vapor sensor out o...

Страница 15: ...sends power to the relay which then closes the relay contacts 4 The control starts the ignition process by providing a spark at the pilot electrode and allowing gas to flow to the pilot 5 When the pil...

Страница 16: ...16 Notes...