Page 18
Bradford White Corp.
Figure 15. Hydronic Piping — Low temp system.
INLET TEMPERATURE °F
50°F
60°F
70°F
GPM
TEMP RISE °F
1.0
100 90 81
2.0
90 83 79
3.0
78 76 68
4.0
59 56 51
INLET TEMPERATURE °C
10°C 16°C 21°C
LPM
TEMP RISE °C
4
56 50 45
8
50 46 44
11
43 42 38
15
33 31 28
Table 8. DHW and Pump Performance Data.
Caution
Scalding Risk: Bradford White recommends
the use of a thermostatic mixing
valve at domestic hot water
outlet (boiler location) to
reduce potential for scalding.
The following thermostatic
mixing valve model has been
tested and approved for
Brute Elite application:
Honeywell AM100-US-1
Contact Bradford White for additional recommended
models.
Installer to provide and install
(anti-scald) thermostatic mixing valve.