Bradford White BRUTE DELUXE BMT2H Скачать руководство пользователя страница 33

Page 33

Brute Deluxe

 (

500-2000), Install & Operating

IItem

 

Description

 

Size

 

Size

 

Size

 

Size

 

Size

 

Size

 

Size

 

 

500

 

750

 

1000

 

1250

 

1500

 

1750

 

2000

 

Sheet Metal Components – 

See Figure 23

 

      

Panel, Jacket, Front

 

5F3320

 

7F3320

 

10F3320

 

12F3320

 

15F3320

 

17F3320

 

20F3320

2A

 

Panel, Jacket, Side, Lower Left

 

5F3420

 

5F3420

 

5F3420

 

5F3420

 

5F3420

 

5F3420

 

5F3420

2B

 

Panel, Jacket, Side, Lower Right

 

5F3421

 

5F3421

 

5F3421

 

5F3421

 

5F3421

 

5F3421

 

5F3421

3A

 

Panel, Jacket, Side, Lower Left 

 

5F3520

 

5F3520

 

5F3520

 

5F3520

 

5F3520

 

5F3520

 

5F3520

3B

 

Panel, Jacket, Side, Lower Right

 

5F3521

 

5F3521

 

5F3521

 

5F3521

 

5F3521

 

5F3521

 

5F3521

Panel, Side, 

Top Left, Jacket 

 

5F3400

 

5F3400

 

5F3400

 

5F3400

 

5F3400

 

5F3400

 

5F3400

Panel, Side, 

Top Right, Jacket 

 

5F3501

 

5F3501

 

5F3501

 

5F3501

 

5F3501

 

5F3501

 

5F3501

Panel, Rear

, Jacket

 

5F3220

 

7F3220

 

10F3220

 

12F3220

 

15F3220

 

17F3220

 

20F3220

Panel, 

Top, Jacket

 

5F3021

 

7F3021

 

10F3021

 

12F3021

 

15F3021

 

17F3021

 

20F3021

W

eldment, V

ent Plate

 

5F3100

 

7F3100

 

7F3100

 

12F3100

 

12F3100

 

12F3100

 

20F3100

W

eldment, Housing, 

Air Inlet/Filter

 

5F3800

 

5F3800

 

10F3800

 

 12F3800

 

 12F3800

 

 12F3800

 

20F3800

10

 

Panel, 

Access, Filter

 

5F3701

 

5F3701

 

5F3701

 

12F3701

 

12F3701

 

12F3701

 

12F3701

11

 

Filter

, Combustion 

Air

 

A2088700

 

A2088700

 

A2088700

 

A2088700

 

A2088700

 

A2088700

 

A2088700

  

(1)

 

(1)

 

(1)

 

(2)

 

(2)

 

(2)

 

(2)

12

 

Panel, Enclosure, Pump

 

5F3015

 

5F3015

 

5F3015

 

5F3015

 

5F3015

 

5F3015

 

5F3015

13

 

Cover

, Housing, Pump

 

5F3016

 

5F3016

 

5F3016

 

5F3016

 

5F3016

 

5F3016

 

5F3016

14

 

Cover

, Pipe, 

Gas 

Manifold

 

5F3304

 

5F3304

 

10F3304

 

20F3304

 

20F3304

 

20F3304

 

20F3304

  

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

Internal Components – 

See Figure 24

 

      

16

 

Assembly

, Base

 

5F1020

 

7F1020

 

10F1020

 

12F1020

 

15F1020

 

17F1020

 

20F1020

17

 

Panel, Front, Combustion Chamber

 

5F2003

 

7F2003

 

10F2003

 

12F2003

 

15F2003

 

17F2003

 

20F2003

18

 

Panel, Rear

, Combustion Chamber

 

5F2006

 

7F2006

 

10F2006

 

12F2006

 

15F2006

 

17F2006

 

20F2006

19

 

Panel, 

Top, Combustion Chamber

 

5F2001

 

7F2001

 

10F2001

 

12F2001

 

15F2001

 

17F2001

 

20F2001

20

 

W

eldment, Chamber

, Left Side, Bottom

 

5C2602

 

5C2602

 

5C2602

 

5C2602

 

5C2602

 

5C2602

 

5C2602

21

 

W

eldment, Chamber

, Right Side. Bottom

 

5C2202

 

5C2202

 

5C2202

 

5C2202

 

5C2202

 

5C2202

 

5C2202

22

 

Panel, Chamber

, Left/Right Side, 

Top

 

5C2002

 

5C2002

 

5C2002

 

5C2002

 

5C2002

 

5C2002

 

5C2002

  

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

 

(2)

23

 

Assembly

, Sight Glass

 

10956000

 

10956000

 

10956000

 

10956000

 

10956000

 

10956000

 

10956000

24

 

Panel, Left Side, 

Air Box

 

5F2015

 

5F2015

 

5F2015

 

5F2015

 

5F2015

 

5F2015

 

5F2015

25

 

Panel, Right Side, 

Air Box

 

5F2016

 

5F2016

 

5F2016

 

5F2016

 

5F2016

 

5F2016

 

5F2016

26

 

Panel, 

Access, 

Air Box

 

5F2004

 

7F2004

 

10F2004

 

12F2004

 

15F2004

 

17F2004

 

20F2004

27

 

Cover

, Access Panel, 

Air Box

 

5F2005

 

5F2005

 

5F2005

 

5F2005

 

5F2005

 

5F2005

 

5F2005

  

(1)

 

(1)

 

(1)

 

(2)

 

(2)

 

(2)

 

(2)

28

 

Divider

, Chamber

, Upper

, Air Box

 

 

 

 

15F2005

 

15F2005

 

 

29

 

Divider

, Chamber

, Lower

, Air Box

 

 

 

 

15F2002

 

15F2002

 

 

30

 

Divider

, Front Chamber

, Combustion Chamber

 

 

 

 

 

 

20F2002

 

20F2002

31

 

Assembly

, Exhaust Stack

 

5F2027

 

7F2027

 

7F2027

 

12F2027

 

12F2027

 

12F2027

 

12F2027

Содержание BRUTE DELUXE BMT2H

Страница 1: ...r d essence ni d autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareils Ne to...

Страница 2: ...Heaters 4B 1 Water System Piping Water Heater 14 4B 2 Hot Water Supply Piping Water Heater 15 4B 3 Water Flow Requirements Water Heater 15 4B 4 Combined Water Heating potable and Space Heating Water H...

Страница 3: ...White factory or local factory representative with any issues or questions regarding this equipment Experience has shown that most operating issues are caused by improper installation The Brute Delux...

Страница 4: ...ry items are shipped in separate packages Verify receipt of all packages listed on the packing slip Inspect everything for damage immediately upon delivery and advise the carrier of any shortages or d...

Страница 5: ...ump is sized for 30 feet 9 1m of piping If the appliance must be installed with longer piping runs then larger diameter pipe or tubing shall be used Consult the factory for assistance Figure 1 Dimensi...

Страница 6: ...gure 2 Dimensional Data pump mounted models HORIZONTAL INTAKE AIR VENT COLLAR VENT PIPE PIPE MAX PIPE MAX NO SIDE WALL SIDE WALL SIZE SIZE DIAMETER DIAMETER LENGTH OF ELBOWS VENT COMBUSTION TERMINAL A...

Страница 7: ...ings shall communicate directly or by ducts with the outdoors or spaces that freely communicate with the outdoors When directly communicating with the outdoors or when communicating to the outdoors th...

Страница 8: ...he vent system must conform to the National Fuel Gas Code ANSI Z223 1 Latest Edition in the U S or in Canada to CSA B149 1 latest edition The vent system must be sized and installed for a Category I F...

Страница 9: ...appliances with condensing vents are not permitted to terminate above a public walkway or over an area where condensate or vapor could create a nuisance or hazard 3 Locate the vent terminal so that v...

Страница 10: ...t 3 feet 91 cm above if within 10 feet 3 m 6 feet 1 83 m horizontally Vent termination not allowed in this location Vent termination not allowed in this location for category IV appliances A vent shal...

Страница 11: ...ight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half in...

Страница 12: ...fans such as range hoods and bathroom exhausts so they will operate at maximum speed Do not operate a summer exhaust fan Close fireplace dampers 4 Place in operation the appliance being inspected Foll...

Страница 13: ...ring any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 45kpa 9 The unit must be isolated from the gas supply system by closing its individual manual shutoff valve during an...

Страница 14: ...he system To ensure a proper operating temperature leading to long boiler life a flow rate has been established based on the fluid temperature rise for this specific size boiler Pump mounted boilers c...

Страница 15: ...including copper if the water is moved too quickly The water flow requirements for the Brute Deluxe water heater are based upon the hardness of the water The water flow is kept high enough to prevent...

Страница 16: ...Page 16 Bradford White Corp Figure 6 Hydronic Piping Multiple Boilers Primary Secondary System Figure 7 Hydronic Piping Multiple Boilers Low Temperature System...

Страница 17: ...Page 17 Brute Deluxe 500 2000 Install Operating Figure 8 Hydronic Piping One Boiler Multi Temperature System Figure 9 Hydronic Piping Primary Secondary Reverse Return...

Страница 18: ...Page 18 Bradford White Corp Figure 10 Hydronic Piping Primary Secondary Reverse Return Low Temperature Figure 11 Water Heater Piping One Heater One Tank...

Страница 19: ...Page 19 Brute Deluxe 500 2000 Install Operating Figure 12 Water Heater Piping Multiple Heaters One Tank Figure 13 Water Heater Piping One Heater Multiple Tanks...

Страница 20: ...19 170 257 341 0 6 1 1 1 9 21 14 10 1250 68 68 90 3 8 3 8 6 3 31 31 24 257 257 341 1 2 1 2 1 9 17 17 13 1500 68 68 90 3 9 3 9 6 5 38 38 28 257 257 341 1 2 1 2 2 0 21 21 16 1750 68 68 90 4 0 4 0 6 7 4...

Страница 21: ...rk on or around the boiler may be standing on wet floors and could be electrocuted by an ungrounded boiler Single pole switches including those of safety controls and protective devices must not be wi...

Страница 22: ...BLOWER 1 LOW HIGH LOW HIGH K1 K2 K1 K2 F2 35 67 F2 35 67 F1 35 67 F1 35 67 K3 HSI 2 HSI 1 120 VAC DPDT MAIN POWER SWITCH S2 S2 35 67 35 67 L2 35 67 L2 35 67 BD 1 IGN S1 S1 35 67 35 67 35 67 L1 35 67 J...

Страница 23: ...Page 23 Brute Deluxe 500 2000 Install Operating Figure 19 Brute Deluxe 500 750 Connection Diagram...

Страница 24: ...Page 24 Bradford White Corp Figure 20 Brute Deluxe 1000 Connection Diagram...

Страница 25: ...K W L2 LOAD 1 1 2 3 4 5 6 7 8 9 10 10 lockout indicator T stat lockout indicator G Pressure Switch Gas Valve 24V Ground Remote Sense S1 L1 L2 S2 Fenwal F1 F2 lockout indicator T stat lockout indicator...

Страница 26: ...tiple boiler control BAS etc wire Stage 1 to the terminals marked Input Stage 1 and Stage 1 and wire Stage 2 to the terminals marked Input Stage 2 and Stage 2 The Local Remote selector switch above th...

Страница 27: ...ll bleeding devices and open make up water valve Allow system to fill slowly 2 If make up water pump is employed adjust pressure switch on pumping system to provide a minimum of 12 psi 81 8 kPa at the...

Страница 28: ...but with differing reductions in output At elevations higher than 7700 ft 2347 m the reduction in output will exceed 10 and at elevations below 7700 ft 2347 m it will be less than 10 High altitude adj...

Страница 29: ...ist in these adjustments are a CO2 or O2 Analyzer and a U Tube Manometer or other device capable of reading a pressure of 2 5 3 0 inches W C 0 62 0 75 kPa Start the adjustment process by checking the...

Страница 30: ...ore and after the valve and remove the valve Re install in reverse order Ensure o rings are properly installed for both inlet and outlet Turn on manual gas shutoff valve and 120 volt power and check a...

Страница 31: ...al gas valve on the heater 3 Disconnect and remove the wires conduit and sensors from all components that are attached to the inlet outlet header 4 Isolate the heat exchanger from the water supply 5 D...

Страница 32: ...esentative to discuss possible remedies 8 4 Short Cycling Water Heater Short cycling will generally occur only in combination space heating and water heating applications when the water heater is oper...

Страница 33: ...F3015 5F3015 5F3015 13 Cover Housing Pump 5F3016 5F3016 5F3016 5F3016 5F3016 5F3016 5F3016 14 Cover Pipe Gas Manifold 5F3304 5F3304 10F3304 20F3304 20F3304 20F3304 20F3304 2 2 2 2 2 2 2 Internal Compo...

Страница 34: ...2018000 T2017400 T2018000 T2017400 45 Tile Bottom Center T2015900 T2015900 T2015900 T2015900 1 1 2 2 Gas Train Components See Figure 24 46 Blower A2111900 A2111900 A2111900 A2111900 A2111900 A2111900...

Страница 35: ...59 Low Water Cutoff optional E2076500 E2076500 E2076500 E2076500 E2076500 E2076500 E2076500 60 Gauge Temperature Pressure A0079000 A0079000 A0079000 A0079000 A0079000 A0079000 A0079000 62 Tee Adapter...

Страница 36: ...E0093200 E0093200 E0093200 79 Panel Mounting Limits Ignition Control 5F7001 5F7001 5F7001 5F7001 5F7001 5F7001 5F7001 80 Panel Cover High Limit Ignition Control 5F7003 5F7003 5F7003 5F7003 5F7003 5F70...

Страница 37: ...Page 37 Brute Deluxe 500 2000 Install Operating Figure 23 Sheet Metal Components...

Страница 38: ...Page 38 Bradford White Corp Figure 24 Internal Components...

Страница 39: ...001800 1250 A2001800 1500 A2001900 1750 A2001900 2000 A2109700 Brute Deluxe Water Heater Size Pump p n Soft Water Normal Water Hard Water 500 A2001700 A2001700 A2001900 750 A2001700 A2001700 A2001900...

Страница 40: ...Bradford White Corporation reserves the right to change specifications components features or to discontinue products without notice 200 Lafayette St Middleville MI 49333 Warranty 800 531 2111 www Br...

Отзывы: