5
Install Guide - SleekWall
STEP-BY-STEP
GUIDE
POST
INSTALLATION
STANDARD ‘POST CENTRE TO POST CENTRE’ GUIDE
The table below allows you to work out what
your post centres will be. If you have 1780mm
paling [allowing for 10mm either side for the
channel] and you are using 65 x 65 posts then
you will have an 1865mm post centre to post
centre.
This also shows the in-between measurements,
should you be fitting your paling between posts
other than a 65 x 65 profile, i .e. timber posts ot
concrete blocks etc.
TGV Paling Length
65 x 65
Post Hole Centres
In-between Post
Measurements
1780mm Paling
1865mm
1800mm
Wall Height
Hole Depth into
Firm Earth or Clay
900mm
450mm
1200mm
550mm
1500mm
600mm
1800mm
600mm
Please note that 1800mm is the standard height. Heights lower than
1800mm can be done using these components, with wastage.
!
IMPORTANT
For higher walls you will need
engineering advice beyond the scope of
this publication.
!
IMPORTANT
The diameter of your holes should be
large enough to have a minimum of
75mm clearance around the post.
!
IMPORTANT
When using vertical conversion kit, post centre may differ depending on desired outcome