26
|
Installation
6 720 644 143 (2010/09)
6.4
Pre-installing pipes
B
Hook mounting rail into the mounting plate.
B
Position mounting plate against the wall, observing
minimum side clearances of 100 mm (
Æ
page 9).
B
Mark out four holes:
–
One of holes A
–
One of holes B
–
Hole C
–
Hole D
B
Drill Ø 10 mm holes.
Fig. 15 Mounting plate
B
Secure mounting plate with mounting rail to the wall
using the screws provided; do not tighten the two
lower screws.
B
Hook in pre-plumbing jig and tighten screws.
Gas and water connections
Fig. 16 Pipe connections
Additional adaptors are provided in the fittings kit for
easy connection.
6 720 615 662-06.1O
A
B
C
D
It is very important to ensure that pipes
are not secured in such a way that the
fittings come under strain.
Ø 3/4"
Ø 1/2"
Ø 3/4"
Ø 1/2"
Ø 3/4"
6 720 644 143-07.1O
65
65
65
65
340
28
55
75
85
364
370
158
120
R 3/4"
R 1/2"
R 3/4"
R 1/2"
R 3/4"
Содержание ZSB 30-2 A