Fault mode
|
69
6 720 644 143 (2010/09)
FA
A flame is detected after the gas has been
switched off.
B
Check gas valve; replace if required.
B
Clean condensate trap.
B
Check electrodes and lead; replace if required.
B
Check flue gas system; clean or repair if required.
Fd
Reset was pressed in error.
B
Press reset again.
B
Check cable harness to high limit safety cut-out and gas
valve for earth connection.
Display
code
Description
Remedy