Fault mode
|
71
6 720 644 143 (2010/09)
17.4 Sensor values
17.4.1 Outside temperature sensor (for weather-
compensated controllers, accessory)
17.4.2 Flow and DHW sensors
17.5 Code Plug
Outside temperature / °C
Testing tolerance
±
10%
Resistance (
Ω
)
-20
2 392
-16
2 088
-12
1 811
-8
1 562
-4
1 342
0
1 149
4
984
8
842
10
781
15
642
20
528
25
436
Table 29
Temperature/ °C
Measuring tolerance
±
10 %
Resistance (k
Ω
)
20
14 772
25
11 981
30
9 786
35
8 047
40
6 653
45
5 523
50
4 608
55
3 856
60
3 243
65
2 744
70
2 332
75
1 990
80
1 704
85
1 464
90
1 262
95
1 093
100
950
Table 30
Appliance
Number
ZSB 30-2 A 23
8 714 431 018 0
ZSB 30-2 A 31
8 714 431 019 0
ZWB 37-2 A 23
8 714 431 014 0
ZWB 37-2 A 31
8 714 431 015 0
Table 31