EXPERT MENU (FOR QUALIFIED TECHNICIANS ONLY)
6 720 644 593 (2010/04)
9
Expert menu (for qualified technicians only)
The Expert menu is used to set the programmer to suit the specifics of the solar heating system.
B
To switch to the Expert menu, press and hold the
button for 5 seconds.
If no entry is made for more than 60 seconds, the controller exits the Expert menu.
9.1 Expert menu functions
Menu
Submenu
Page
Language
Time
System configuration
Basic system - 1: standard DHW system (configuration
diagrams)
Basic system - 2: Back-up heating (configuration diagrams)
Settings
1: Standard system (pump SP, collector temperatures/type)
2: Back-up heating (valve DWU1)
A: 2nd collector array (pump PA)
B: Recharge system (pump PB)
C: Priority secondary (pump PC, valve DWUC/DWU3)
D: External heat exchanger (pump PD, anti-icing system,
cylinder top temperature limiter, valve DWUD)
E: Thermal disinfection (pump PE)
Solar yield (heat meter)
Cooling function
Water filled system function
Start solar system
For switching solar heating system on or off
Reset
For resetting the programmer to the default settings
Tab. 11