WFL 2060 Service Tips
WFL 2060 Service Tips
--
--
Resistance
Resistance
Measurements from Control Module (1)
Measurements from Control Module (1)
69
1st Edition/Revision 5 (1/20/04)
Top
Top
1
1
Disconnect & measure
white 5-pin
connector (with
3
black
wires) to measure dual cold water valve. Valve
should read (pin 1 is at bottom):
•
Main wash (pins 1-3): 2.7 - 4.5 k
Ω
•
Prewash (pins 1-5):
2.7 - 4.5 k
Ω
Disconnect & measure
blue
2-
pin
connector (with
blue
wires) to measure drain pump.
Pump should read ~ 80 - 94
Ω
Disconnect & measure
tan
3-pin
connector (with
2
black
wires) to measure NTC. NTC should read:
•
20ºC (68ºF): 5.4 - 6.5 k
Ω
•
30ºC (86ºF): 3.5 - 4.3 k
Ω
•
40ºC (104ºF):
2.3 - 2.9 k
Ω
Disconnect & measure
tan
3-pin
connector (with
2 black
wires) to
measure hot water valve. Valve
should read 2.7 - 4.5 k
Ω
.
WARNING
! Unplug washer before making any resistance measurements.
Содержание WFL 2060UC
Страница 14: ...Operation Operation Fascia Panels Fascia Panels 14 WFL 2060UC WFR 2460UC 1st Edition Revision 5 1 20 04 ...
Страница 34: ...Disassembly Disassembly Drum Drive Motor Drum Drive Motor 34 1st Edition Revision 5 1 20 04 ...
Страница 37: ...WFL 2060UC Circuit Diagram WFL 2060UC Circuit Diagram 37 1st Edition Revision 5 1 20 04 ...
Страница 39: ...WFR 2460UC Circuit Diagram WFR 2460UC Circuit Diagram 39 1st Edition Revision 5 1 20 04 ...