WFR 2460 Service Tips
WFR 2460 Service Tips
--
--
Configuring
Configuring
Replacement Control Modules
Replacement Control Modules
43
NOTE:
Note original equipment washer modules are
factory configured and CANNOT be changed in the field.
4
2010011 T5: Variant
Max. spin speed
2!
1000 RPM
3!
1100 RPM
4!
1200 RPM
5!
1300 RPM
6!
1400 RPM
7!
1500 RPM
8!
1600 RPM
Language
0!
German
1!
English
2!
French
3!
Dutch
4!
Italian
5!
Spanish
E!
Polish
Replacement
WFR 2460
control modules
(#
484014
) aren’t configured. Please
follow these instructions to configure
replacement modules.
Water inlet
0!
Without Aqua
stop, cold water
1!
With Aqua stop,
cold water
2!
Without Aqua
stop, hot water
Push
Menu
button to select 1st #
for max. spin speed (until 1st #
flashes), then push
Select
button
until “4” (for 1200 RPM max.) is
chosen. Push
Start/Pause
button
to save setting.
Push
Menu
button to select 2nd #
for water inlet (until 2nd #
flashes), then push
Select
button
until “2” (hot water) is chosen.
Push
Start/Pause
button to save
setting.
Push
Menu
button to select 7th #
for language (until 7th # flashes),
then push
Select
button until “1”
(for English) is chosen. Push
Start/Pause
button to save setting.
•
After installing module, enter test program by first
pushing and holding
Menu
&
Select
buttons, then
rotating selector switch (dial) ccw to
Permanent
Press Cold
(until display comes on).
•
Push
Menu
button repeatedly to scroll to test
“T5”:
Model Variant Coding
.
Red
light on
Start/Pause
button will be flashing. Push
Start/Pause
button to
enter test
T5
to change #’s (
red
light will stop
flashing when test
T5
has been entered).
•
Push
Menu
button to scroll to each # (when desired
# is flashing). For each #, push
Select
button until
correct setting is chosen, then push
Start/Pause
button to save setting. Repeat until settings for all
eight #’s are saved -- U.S. washers
must
show
42010011
.
•
When settings for all eight #’s are saved, exit test
program by rotating selector switch (dial) cw to
Off
.
NOTE: See test program page 61
for all test T5 settings.
4
2
010011 T5: Variant
420100
1
1 T5: Variant
Sample Displays
1st Edition/Revision 5 (1/20/04)
Содержание WFL 2060UC
Страница 14: ...Operation Operation Fascia Panels Fascia Panels 14 WFL 2060UC WFR 2460UC 1st Edition Revision 5 1 20 04 ...
Страница 34: ...Disassembly Disassembly Drum Drive Motor Drum Drive Motor 34 1st Edition Revision 5 1 20 04 ...
Страница 37: ...WFL 2060UC Circuit Diagram WFL 2060UC Circuit Diagram 37 1st Edition Revision 5 1 20 04 ...
Страница 39: ...WFR 2460UC Circuit Diagram WFR 2460UC Circuit Diagram 39 1st Edition Revision 5 1 20 04 ...